본문 바로가기

Diagnostic performance of artificial intelligence-based coronary artery analysis in the emergency department: A multicenter study

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q1Scopus Q1
피인용
Scopus 0
JCR IF
JCR 2024 5.8
ISSN
1934-5925

저자

  1. 이지원A제1저자Department of Radiology, Pusan National University Hospital, Pusan National University School of Medicine and Medical Research Institute, Busan, Republic of Korea
  2. Han, KyunghwaDepartment of Radiology, Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea
  3. Kim, Jin YoungDepartment of Radiology, Dongsan Medical Center, Keimyung University School of Medicine, Daegu, Republic of Korea
  4. Lee, Kye HoDepartment of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul and Dankook University Hospital, Cheonan, Republic of Korea
  5. Im, Dong JinDepartment of Radiology, Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea
  6. Kim, Na YoungDepartment of Radiology, Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea
  7. Choi, Byoung WookDepartment of Radiology, Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea
  8. Schöbinger, MaxSiemens Healthineers AG, Forchheim, Germany
  9. Pak, SeongyongSiemens Healthineers, Seoul, Republic of Korea
  10. Hur, Jin교신저자Department of Radiology, Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea

초록

Rationale and objectives: On-premise artificial intelligence (AI) software may enable rapid interpretation of coronary CT angiography (CCTA) in the emergency department (ED), although its diagnostic performance relative to invasive coronary angiography (ICA) remains uncertain. We aimed to evaluate the diagnostic performance of an AI-based coronary artery analysis software for detecting obstructive coronary artery disease (CAD) (CAD-RADS ≥3) in ED patients with acute chest pain, using expert consensus and ICA as separate reference standards. Materials and methods: In this retrospective multicenter study, 1193 patients with acute chest pain who underwent CCTA across four academic EDs (January 2019–August 2024) were analyzed using on-premise AI software. Diagnostic performance for detecting obstructive CAD was evaluated in two cohorts, using expert consensus (n ​= ​885) and ICA (n ​= ​308) as reference standards. Overall, 342 patients (28.7%) had obstructive CAD. Results: Using expert consensus, AI achieved a sensitivity of 79.5% and a negative predictive value (NPV) of 95.4%. With ICA as the reference, sensitivity and NPV were 94.6% and 89.2%, respectively. AI and expert radiologists showed comparable sensitivity (94.6% vs 95.2%; P ​= ​0.56), NPV (89.2% vs 91.4%; P ​= ​0.20), and area under the curve (0.87 vs 0.87; P ​= ​0.86), although AI demonstrated lower specificity (68.0% vs 78.7%) and positive predictive value (PPV) (81.8% vs 87.2%) (both P ​< ​0.001). Conclusion: On-premise AI provides high sensitivity and NPV for excluding obstructive CAD, comparable to expert radiologists, although specificity and PPV were significantly lower. These findings support its role as a second-reader and clinical decision-support tool in emergency settings.