Fractional flow reserve measurement using dynamic CT perfusion imaging in patients with coronary artery disease
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- ESCIScopus
- 저널
- RADIOLOGY ADVANCES1(4) · 2024
- 피인용
- Scopus 1
- ISSN
- 2976-9337
저자
- So, Aaron제1저자교신저자Imaging, Lawson Research Institute, London, ON N6A 4V2, Canada
- 추기석Radiology, Pusan National University School of Medicine and Medical Research Institute, Pusan National University Yangsan Hospital, Yangsan-si, Gyeongsangnam-do 50612, Korea
- 이지원ARadiology, Pusan National University School of Medicine and Medical Research Institute, Pusan National University Hospital, Busan 49241, Korea
- Kim, Yun-HyeonRadiology, Chonnam National University Medical School, Chonnam National University Hospital, Gwangju 61469, Korea
- Haider, MustafaMedical Biophysics, Schulich School of Medicine and Dentistry, Western University, London, ON N6A 5C1, Canada
- Hasan, MahmudMedical Biophysics, Schulich School of Medicine and Dentistry, Western University, London, ON N6A 5C1, Canada
- El-Ganga, SeragMedical Biophysics, Schulich School of Medicine and Dentistry, Western University, London, ON N6A 5C1, Canada
- Goela, AkshayeMedical Biophysics, Schulich School of Medicine and Dentistry, Western University, London, ON N6A 5C1, Canada
- Teefy, PatrickCardiology, London Health Sciences Centre, London, ON N6A 5W9, Canada
- Choe, Yeon Hyeon교신저자Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06351, Korea
초록
Purposes: The objective was to evaluate the accuracy of a novel CT dynamic angiographic imaging (CT-DAI) algorithm for rapid fractional flow reserve (FFR) measurement in patients with coronary artery disease (CAD). Materials and Methods: This retrospective study included 14 patients (age 58.5 ± 10.6 years, 11 males) with CAD who underwent stress dynamic CT myocardial perfusion scanning with a dual-source CT scanner. The included patients had analyzable proximal and distal coronary artery segments adjacent to the stenosis in the perfusion images and had corresponding invasive catheter-based FFR measurements for that stenosis. An in-house software based on the CT-DAI algorithm was used to compute FFR using the pre- and post- lesion coronary time-enhancement curves obtained from the stress myocardial perfusion images. The CT-DAI derived FFR values were then compared to the corresponding catheter-based invasive FFR values. A coronary artery stenosis was considered functionally significant for FFR value <0.8. Results: The CT-DAI derived FFR values were in agreement with the invasive FFR values in all 15 coronary arteries in 14 patients, resulting in 100% per-vessel and per-patient diagnostic accuracy. FFR derived using CT-DAI (M = 0.768, SD = 0.156) showed an excellent linear correlation (R = 0.910, P < .001) and statistical indifference (P= .655) with that measured using invasive catheter-based method (M = 0.796, SD = 0.149). Bland-Altman analysis showed no significant proportional bias. Conclusion: The novel CT-DAI algorithm can reliably compute FFR across a coronary artery stenosis directly from dynamic CT myocardial perfusion images, facilitating rapid on-site hemodynamic assessment of the epicardial coronary artery stenosis in patients with CAD.
키워드
coronary artery diseasedynamic CT myocardial perfusion imagingfractional flow reserve
식별자
- Scopus EID
- 2-s2.0-105050665588



로그인
연구물 목록으로