CAAL: EEG-guided cross-modal adaptive alignment for learning consistent representations in EEG-fNIRS fusion
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널
- INFORMATION FUSION138 · #104729 · 2027
- 피인용
- Web of Science 0Scopus 0
- FWCI (Scopus)
- 0
- ISSN
- 1566-2535
저자
- Fu, Baole제1저자Jilin Univ, Natl Key Lab Automot Chassis Integrat & B, Changchun 130022, Peoples R China
- Gao, Jinwu교신저자Jilin Univ, Natl Key Lab Automot Chassis Integrat & B, Changchun 130022, Peoples R China
- Hou, ShengyanJilin Univ, Natl Key Lab Automot Chassis Integrat & B, Changchun 130022, Peoples R China
- Jia, ZhihuanJilin Univ, Natl Key Lab Automot Chassis Integrat & B, Changchun 130022, Peoples R China
- Liu, Yinhua교신저자Qingdao Univ, Inst Future, Qingdao 266071, Peoples R China
- 홍금식Pusan Natl Univ, Sch Mech Engn, Pusan 46241, South Korea
초록
Multimodal fusion leveraging the high temporal resolution of electroencephalography (EEG) and the stable spatial representations of functional near-infrared spectroscopy (fNIRS) enables comprehensive neural activity decoding. However, due to the hemodynamic response mechanism, fNIRS exhibits an inherent temporal delay relative to EEG, leading to temporal misalignment and inconsistencies in cross-modal representations in EEGfNIRS fusion. Therefore, this paper proposes a cross-modal adaptive alignment learning (CAAL) framework. A spatiotemporal feature extraction module incorporating functional connectivity priors captures both spatial dependencies and temporal dynamics. An EEG-guided cross-modal alignment module uses EEG features as modulation signals to guide fNIRS representations within a shared latent space under explicit consistency constraints. Furthermore, to reduce reliance on empirical hyperparameter tuning, an adaptive multi-fidelity optimization strategy identifies efficient and saturation points on learning curves for adaptive fidelity selection. Experiments on three public EEG-fNIRS datasets, including motor imagery (MI), mental arithmetic (MA), and word generation (WG), demonstrate the effectiveness of CAAL. CAAL achieves promising performance, with average accuracies of 74.14% for MI, 87.07% for MA, and 83.33% for WG in intra-subject evaluations. Ablation studies validate that EEG-guided alignment effectively enhances cross-modal fusion performance.
키워드
Cross-modal alignmentElectroencephalography (EEG)Functional near-infrared spectroscopy (fNIRS)Brain functional connectivityMulti-fidelity optimization