A PACIFIER-TYPE LOW-PRESSURE MONITORING HARDWARE SYSTEM FOR QUANTITATIVE INFANT NONNUTRITIVE SUCKING ASSESSMENT
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q4Scopus Q4
- 저널
- JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY26(8) · 2026
- 피인용
- Web of Science 0Scopus 0
- FWCI (Scopus)
- 0
- JCR IF
- JCR 2024 0.6
- ISSN
- 0219-5194
저자
- Seo, Ho-young제1저자Kyungpook Natl Univ, Grad Sch, Dept Med & Biol Engn, 680 Gukchaebosang Ro, Daegu 41944, South Korea
- Kim, Myoung namKyungpook Natl Univ, Sch Med, Dept Biomed Engn, 680 Gukchaebosang Ro, Daegu 41944, South Korea
- Jung, Young-jinChonnam Natl Univ, Sch Biomed Engn, 50 Daehak Ro, Jeonnam Gwangju 59626, Yeosu, South Korea
- Lee, Gihyoun교신저자Chonnam Natl Univ, Sch Biomed Engn, 50 Daehak Ro, Jeonnam Gwangju 59626, Yeosu, South Korea
- 박지수교신저자Pusan Natl Univ, Res Inst Korean Med, 270 Megi Ro, Yangsan Si 50615, Gyeongsangnam D, South Korea
초록
Nonnutritive sucking (NNS) is an early oral-motor behavior that reflects infant neuromotor maturation and feeding readiness, yet bedside NNS assessment remains largely subjective and examiner-dependent. We developed a pacifier-type low-pressure monitoring hardware system integrating a pacifier-linked air-pressure pathway, I2C-based pressure-sensor interface, microcontroller unit (MCU), display module, USB serial communication and buzzer feedback. The firmware supports a 60s timed measurement workflow and outputs eight NNS-derived features: burst duration, pressure amplitude, peak count, intra-burst frequency, peak interval average time, cycles per burst, burst count and pause average time (PAT). A subject-wise analysis pipeline was defined for raw-data inventory, waveform quality control, feature extraction and generation of publication-ready tables and figures. The system is intended as a reproducible research hardware platform for infant NNS pressure-signal acquisition, operational workflow testing and structured dataset construction. Formal bench calibration, repeatability testing and clinical validation remain necessary before the system can be interpreted as a quantitatively validated measurement device. Following successful clinical validation, the proposed system may support objective assessment of infant feeding readiness and early identification of infants at risk for feeding difficulties in clinical settings.
키워드
Nonnutritive suckinginfantpacifierpressure sensororal pressurebiomedical hardwareneonatal feedingORAL-FEEDING SKILLSPRETERMCOORDINATIONRESPIRATIONMATURATION