Utilization of Saliva for Anti-SARS-CoV-2 Antibody Detection in the General Population
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q4Scopus Q4
- 저널
- CLINICAL LABORATORY72(8) · pp.1727 · 2026
- 피인용
- Web of Science 0Scopus 0
- FWCI (Scopus)
- 0
- JCR IF
- JCR 2024 0.6
- ISSN
- 1433-6510
저자
- 신경화제1저자Pusan Natl Univ Hosp, Dept Lab Med, Busan, South Korea
- 유동원Pusan Natl Univ Hosp, Dept Lab Med, Busan, South Korea
- Yu, ShinaeInje Univ, Haeundae Paik Hosp, Dept Lab Med, Busan, South Korea
- 김원주Pusan Natl Univ, Sch Med, Dept Lab Med, Yangsan, Gyeongnam, South Korea
- 이상엽Pusan Natl Univ, Yangsan Hosp, Dept Family Med, Yangsan, Gyeongnam, South Korea
- 이선민교신저자Pusan Natl Univ, Sch Med, Dept Lab Med, Yangsan, Gyeongnam, South Korea
초록
Background: Similar to how salivary cortisol reflects serum cortisol as a stress biomarker, saliva by its easy, noninvasive collection, holds promise for mucosal antibody testing to assess systemic humoral immunity. In this study, we aimed to determine the prevalence of SARS-CoV-2 antibodies in saliva during the COVID-19 pandemic. Methods: Between February and December 2022, paired saliva and serum specimens were collected twice per participant with the history of infection. SARS-CoV-2 antibodies were measured by Roche Elecsys anti-N and Abbott anti-S1-RBD assays. Cortisol was also quantified in serum-saliva paired samples using Elecsys Cortisol II. Saliva antibody results with manufacturer’s serum cutoff were compared with those of the serum. Results: Out of the 166 participants enrolled, the first and second visits showed serum anti-S1-RBD Ab in 162 (97.6%) and anti-N Ab in 79 (47.5%) and 97 (58.4%) participants. At the first and second visits, 14 (8.4%) and 13 (7.8%) participants had salivary anti-S1-RBD Ab, while 4 (2.4%) and 5 (3.0%) participants had anti-N Ab. Agreement between serum and saliva was slight for anti-S1-RBD (κ = 0.004) and poor for anti-N (κ < 0). The mean serum cortisol was 7.52 μg/dL (visit 1) and 7.97 μg/dL (visit 2) versus 0.19 μg/dL and 0.18 μg/dL in saliva. Saliva cortisol levels were ~ 95.5 - 97.6% lower than serum. Conclusions: Salivary SARS-CoV-2 antibody levels and serologic results are poorly concordant, preventing saliva as a direct substitute without assay-specific cutoffs. Salivary cortisol correlates predictably with serum levels but consistently underestimates them. Further work is needed to establish standardized saliva thresholds for both antibodies and cortisol.
키워드
COVID-19 pandemicnon-invasive biomarkersalivaSARS-CoV-2 antibody
식별자
- Scopus EID
- 2-s2.0-105046721367
- WoS UID
- 001898647000013



로그인
연구물 목록으로