본문 바로가기

Deep learning-based reconstruction for multi-shot breast DWI: Quantitative and qualitative improvements

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q1Scopus Q1
피인용
Web of Science 1Scopus 1
FWCI (Scopus)
2.08
JCR IF
JCR 2024 3.3
ISSN
0720-048X

저자

  1. 김진주제1저자Pusan Natl Univ, Pusan Natl Univ Hosp, Biomed Res Inst, Dept Radiol,Sch Med, Busan, South Korea
  2. 김진유교신저자Pusan Natl Univ, Pusan Natl Univ Hosp, Biomed Res Inst, Dept Radiol,Sch Med, Busan, South Korea
  3. 황보리Pusan Natl Univ, Pusan Natl Univ Hosp, Biomed Res Inst, Dept Radiol,Sch Med, Busan, South Korea
  4. 이호준Pusan Natl Univ, Pusan Natl Univ Hosp, Biomed Res Inst, Dept Radiol,Sch Med, Busan, South Korea
  5. 이남경Pusan Natl Univ, Pusan Natl Univ Hosp, Biomed Res Inst, Dept Radiol,Sch Med, Busan, South Korea
  6. Lee, Jong MinSiemens Healthineers Ltd, Seoul 06620, South Korea
  7. Liu, WeiSiemens Healthineers AG, Res & Clin Translat, Magnet Resonance, Erlangen, Germany

초록

Purpose: To evaluate the effectiveness of deep learning (DL)-based reconstruction for improving image quality and reducing scan time in multi-shot diffusion-weighted imaging (DWI) of the breast, compared with standard readout-segmented echo-planar imaging (rs-EPI). Materials and Methods: This retrospective study included 146 women (mean age: 55.8 years) with newly diagnosed breast cancer who underwent preoperative breast MRI with both rs-EPI and prototype DL-reconstructed (DLR) multi-shot DWI. Quantitative metrics—signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), lesion contrast, and apparent diffusion coefficient (ADC)—were compared between sequences. Two radiologists independently assessed overall image quality, artifact suppression, lesion conspicuity, and fibroglandular tissue suppression using a 5-point Likert scale. An independent validation cohort of 39 consecutive patients was analyzed using the same methodology. Results: Compared with rs-EPI, DLR multi-shot DWI demonstrated significantly higher SNR, CNR, and lesion contrast at both b = 800 and synthetic b = 1500 s/mm2 (all p < 0.05). Tumor ADC values were slightly lower and fibroglandular tissue ADC values slightly higher with DLR (both p < 0.05). Qualitative assessments demonstrated higher scores for overall image quality and lesion conspicuity with DLR, with improved artifact suppression at b = 800 s/mm2. Interobserver agreement was substantial to almost perfect (weighted κ = 0.753–0.981). DL reconstruction reduced acquisition time by 29% compared with rs-EPI. In the validation cohort, improvements in SNR, CNR, and overall image quality were also observed, whereas ADC values did not differ significantly between techniques. Conclusion. DL-based reconstruction improves quantitative and qualitative image quality in multi-shot breast DWI while reducing scan time. These findings support its potential integration into clinical breast MRI.

키워드

Breast NeoplasmsDeep LearningDiffusion Magnetic Resonance ImagingEcho-Planar ImagingImage Enhancement

식별자

Scopus EID
2-s2.0-105047010687
WoS UID
001850952200002