Parameter studies for highly concentrated spheroid printing considering nozzle clogging and printing resolution with two-way coupled fluid-particle simulations
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q1Scopus Q1
- 저널
- VIRTUAL AND PHYSICAL PROTOTYPING21(1) · #e2690846 · 2026
- 피인용
- Web of Science 0Scopus 0
- FWCI (Scopus)
- 0
- JCR IF
- JCR 2024 8.8
- ISSN
- 1745-2759
저자
- 이재성제1저자Pusan Natl Univ, Dept Biomed Convergence Engn, Yangsan, South Korea
- Kim, JaewookPohang Univ Sci & Technol POSTECH, Dept Mech Engn, Pohang 37673, South Korea
- Cho, Dong-Woo교신저자Pohang Univ Sci & Technol POSTECH, Dept Mech Engn, Pohang 37673, South Korea
- Jang, Jinah교신저자Pohang Univ Sci & Technol POSTECH, Dept Mech Engn, Pohang 37673, South Korea
- 김병수교신저자Pusan Natl Univ, Dept Informat Convergence Engn Biomed Convergence, Yangsan, South Korea
초록
Spheroid-based bioprinting is essential for reproducing high-cell-density tissues where cell-cell interactions are critical, such as pancreatic tissue. Although spheroids more effectively mimic the in vivo microenvironment compared to conventional culture systems, nozzle clogging remains a major technical challenge that compromises printing resolution and consistency. In this study, we integrated two-way coupled fluid-particle simulations with experimental validation to systematically analyze key factors influencing clogging and resolution stability in high-concentration spheroid printing. Using pancreatic-derived extracellular matrix (pdECM)-based bioink, we analyzed wall shear stress (WSS) and relative velocity distributions under various nozzle geometries and pneumatic conditions. PDMS molding techniques were applied to visualise internal nozzle structures, enabling precise comparisons between experimental and simulation results. Tapered nozzles, particularly 25G and 22G configurations, exhibited more uniform flow characteristics than cylindrical nozzles of equivalent gauge, resulting in reduced shear stress and minimised spheroid aggregation near the nozzle outlet. Optimised nozzle geometry and pneumatic control promoted uniform spheroid distribution while maintaining structural integrity. Notably, the 25G tapered nozzle maintained comparable printing resolution to the 24G cylindrical nozzle while demonstrating significantly more stable extrusion with reduced clogging risk, confirming that nozzle geometry optimisation can simultaneously address both resolution and clogging challenges.
키워드
Spheroid-based bioprintingtwo-way coupled CFD-DEM simulationwall shear stressnozzle geometry optimisation
식별자
- Scopus EID
- 2-s2.0-105047569792
- WoS UID
- 001840020900001



로그인
연구물 목록으로