Physics based coupled thermo-hydraulic framework for steady-state wick-type heat pipe reduced-order modeling
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q1Scopus Q1
- 저널
- APPLIED THERMAL ENGINEERING304 · 2026
- 피인용
- Web of Science 0Scopus 0
- FWCI (Scopus)
- 0
- JCR IF
- JCR 2024 6.9
- ISSN
- 1359-4311
저자
- 쿠남쿠마라스난다쿠마르찬드란제1저자Pusan Natl Univ, Sch Mech Engn, 2 Busandaehak Ro,63Beon Gil, Busan 46241, South Korea
- Chetwynd-Chatwin, JasonRolls Royce Plc, Whittle House,POB 3, Filton BS34 7QE, England
- 하만영교신저자Pusan Natl Univ, Sch Mech Engn, 2 Busandaehak Ro,63Beon Gil, Busan 46241, South Korea
- 민준기교신저자Pusan Natl Univ, Sch Mech Engn, 2 Busandaehak Ro,63Beon Gil, Busan 46241, South Korea
초록
Driven by the need for rapid steady-state wick-type heat pipe analysis, a reduced-order thermo-fluid solver offers a practical alternative to computationally expensive high-fidelity simulations, avoiding experimental closure inputs. However, removing the time-derivative terms from transient lumped formulations yields an underdetermined algebraic system, requiring suitable closure conditions for a solvable reduced-order framework. Accordingly, the heat pipe is modeled as a coupled thermo-fluid lumped thermal resistance network with one-dimensional flow relations, accounting for the fraction of input heat available for working fluid circulation. The underdetermined steady-state system is closed by relating the condenser-side vapor and wick temperatures to the evaporator-side temperatures and vapor pressure drop, thereby providing thermo-fluid coupling through the vapor-core thermal resistance. A Picard-type iterative scheme with temperature and pressure dependent properties then solves the nonlinear algebraic system. The solver captured the steady-state thermal behavior of the validation cases with reasonable accuracy, as reflected by section-wise RMSE values below 0.11. The converged thermal state and effective transport characteristics are used to reconstruct internal transport characteristics through analytical based post-processing relations with physically consistent trends. The framework provides satisfactory prediction of effective thermal performance and capillary operability, with the R∗ comparison yielding MAPER∗=3.33% and MaxRER∗=8.00%. The independent validation cases achieved convergence within 5–9 iterations, with a thermal-solution time below 0.06s, demonstrating the computational efficiency of the framework. These quantitative results indicate that the proposed reduced-order approach provides an efficient and physically informed tool for parametric studies, preliminary design, and surrogate-model development in heat pipe optimization.
키워드
Internal flow transportLumped resistance networkMatrix-based solverSteady-state operationThermal–hydraulic couplingWicked heat pipe
식별자
- Scopus EID
- 2-s2.0-105046410555
- WoS UID
- 001841453400001



로그인
연구물 목록으로