본문 바로가기

Physics based coupled thermo-hydraulic framework for steady-state wick-type heat pipe reduced-order modeling

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q1Scopus Q1
피인용
Web of Science 0Scopus 0
FWCI (Scopus)
0
JCR IF
JCR 2024 6.9
ISSN
1359-4311

저자

  1. 쿠남쿠마라스난다쿠마르찬드란제1저자Pusan Natl Univ, Sch Mech Engn, 2 Busandaehak Ro,63Beon Gil, Busan 46241, South Korea
  2. Chetwynd-Chatwin, JasonRolls Royce Plc, Whittle House,POB 3, Filton BS34 7QE, England
  3. 하만영교신저자Pusan Natl Univ, Sch Mech Engn, 2 Busandaehak Ro,63Beon Gil, Busan 46241, South Korea
  4. 민준기교신저자Pusan Natl Univ, Sch Mech Engn, 2 Busandaehak Ro,63Beon Gil, Busan 46241, South Korea

초록

Driven by the need for rapid steady-state wick-type heat pipe analysis, a reduced-order thermo-fluid solver offers a practical alternative to computationally expensive high-fidelity simulations, avoiding experimental closure inputs. However, removing the time-derivative terms from transient lumped formulations yields an underdetermined algebraic system, requiring suitable closure conditions for a solvable reduced-order framework. Accordingly, the heat pipe is modeled as a coupled thermo-fluid lumped thermal resistance network with one-dimensional flow relations, accounting for the fraction of input heat available for working fluid circulation. The underdetermined steady-state system is closed by relating the condenser-side vapor and wick temperatures to the evaporator-side temperatures and vapor pressure drop, thereby providing thermo-fluid coupling through the vapor-core thermal resistance. A Picard-type iterative scheme with temperature and pressure dependent properties then solves the nonlinear algebraic system. The solver captured the steady-state thermal behavior of the validation cases with reasonable accuracy, as reflected by section-wise RMSE values below 0.11. The converged thermal state and effective transport characteristics are used to reconstruct internal transport characteristics through analytical based post-processing relations with physically consistent trends. The framework provides satisfactory prediction of effective thermal performance and capillary operability, with the R∗ comparison yielding MAPER∗=3.33% and MaxRER∗=8.00%. The independent validation cases achieved convergence within 5–9 iterations, with a thermal-solution time below 0.06s, demonstrating the computational efficiency of the framework. These quantitative results indicate that the proposed reduced-order approach provides an efficient and physically informed tool for parametric studies, preliminary design, and surrogate-model development in heat pipe optimization.

키워드

Internal flow transportLumped resistance networkMatrix-based solverSteady-state operationThermal–hydraulic couplingWicked heat pipe

식별자

Scopus EID
2-s2.0-105046410555
WoS UID
001841453400001