본문 바로가기

Prediction of peak oxygen uptake using interpretable machine learning on routinely available preoperative assessments before lung resection

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q1Scopus Q1
피인용
Web of Science 0Scopus 0
FWCI (Scopus)
0
JCR IF
JCR 2024 3.5
ISSN
2218-6751

저자

  1. 김세훈제1저자교신저자Pusan Natl Univ, Dept Ind Engn, Busan, South Korea
  2. 박사은Pusan Natl Univ, Dept Ind Engn, Busan, South Korea
  3. 홍초희Pusan Natl Univ Hosp, Biomed Res Inst, Busan, South Korea
  4. 박태성Pusan Natl Univ Hosp, Biomed Res Inst, Busan, South Korea
  5. 신명준Pusan Natl Univ Hosp, Biomed Res Inst, Busan, South Korea
  6. 김기훈교신저자Pusan Natl Univ, Dept Ind Engn, Busan, South Korea
  7. 김상훈교신저자Pusan Natl Univ Hosp, Biomed Res Inst, Busan, South Korea

초록

Background: Cardiopulmonary exercise testing is the reference standard for preoperative functional assessment before lung resection, but its use is limited by resource and practical constraints. This study developed and internally evaluated an interpretable machine learning model to estimate preoperative peak oxygen uptake from routine clinical assessments, quantify the contribution of individual predictors to model estimation, and evaluate classification performance at the clinically relevant threshold of 20 mL·kg^-1·min^-1. Methods: This single-centre retrospective study included 320 consecutive patients in South Korea who underwent preoperative treadmill cardiopulmonary exercise testing between April 2018 and March 2024. Thirty-three routinely available predictors, including demographic characteristics, anthropometric measures, pulmonary function results, and bioimpedance-derived indices, were used to train regression models. Model development employed 10 repeats of 5-fold nested cross-validation. The best-performing model was interpreted using Shapley additive explanations. Potential prioritisation performance was assessed by classifying patients with peak oxygen uptake below the prespecified threshold. Results: Random forest showed the best performance, with a root mean square error of 3.750±0.731, a mean absolute error of 2.901±0.599, and a coefficient of determination of 0.323±0.153, indicating moderate explanatory performance for continuous VO_2peak estimation. The most influential predictors were forced expiratory volume in 1 second, forced vital capacity, age, and bioimpedance-derived phase angle. At the threshold of 20 mL·kg^-1·min^-1, the model achieved an area under the receiver operating characteristic curve of 0.842±0.072. Conclusions: This model showed moderate performance for estimating peak oxygen uptake, identified clinically relevant contributors, and may support prioritisation for CPET and consideration of prehabilitation assessment when resources are limited.

키워드

bioelectrical impedance analysisinterpretable machine learningpeak oxygen uptakepreoperative risk assessmentThoracic surgery

식별자

Scopus EID
2-s2.0-105043447789
WoS UID
001821345100006