본문 바로가기

Development of a one-dimensional equivalent thermal network-based prediction model for natural convection heat transfer characteristics in stacked cells

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q1Scopus Q1
피인용
Web of Science 1Scopus 1
FWCI (Scopus)
0
JCR IF
JCR 2024 6.4
ISSN
0735-1933

저자

  1. 이승진제1저자Pusan Natl Univ, Sch Mech Engn, 2,Busandaehak-ro 63beon-gil, Busan 46241, South Korea
  2. 민준기Pusan Natl Univ, Sch Mech Engn, 2,Busandaehak-ro 63beon-gil, Busan 46241, South Korea
  3. 양재성교신저자Pusan Natl Univ, Rolls Royce & Pusan Natl Univ Technol Ctr, 2,Busandaehak-ro 63beon-gil, Busan 46241, South Korea

초록

Using natural convection correlations derived from detailed three-dimensional (3D) computational fluid dynamics (CFD) results, a one-dimensional (1D) Equivalent Thermal Network (ETN) model was developed to efficiently predict the heat transfer characteristics of ten stacked battery cells. By introducing an equivalent thermal conductivity that reflects natural convection effects through average Nusselt number correlations for each cell, the model solves only the energy equation based on Fourier's law. A numerical algorithm was further developed to update the average Nusselt numbers and thermal resistances of the cells and enclosure. The prediction accuracy for cell temperature and heat flux was validated against 3D CFD results under various heat flux conditions in both steady-state and transient analyses. Under steady-state conditions, the temperature error for the 10th cell remains below 1.8°C[jls-end-space/], and the maximum relative error based on the dimensionless temperature θ is below 6.68%[jls-end-space/], indicating good overall agreement. Under transient conditions, the 1D ETN model slightly underpredicts local cell temperatures, with a maximum deviation of 1.22°C[jls-end-space/]. Nevertheless, it captures the key natural convection behavior, with larger temperature rises observed at higher floors. In addition, the model achieves computational cost reductions of 99.6% and 99.9% in steady-state and transient analyses, respectively, demonstrating its effectiveness for early-stage thermal system design.

키워드

CFDEquivalent modelHeat transferNatural convectionThermal network