본문 바로가기

SI-H Eliminated Conductive PDMS Micro Patterns for Ultra Sensitive Temperature Sensor

문서 유형
연구출판물 · 학술대회 발표논문
등재
Scopus
저널 순위
Scopus Q3
피인용
Scopus 0
FWCI (Scopus)
0
ISSN
1084-6999

저자

  1. 황연정제1저자교신저자Pusan National University, Department of Information Convergence Engineering, REPUBLIC OF KOREA
  2. Na, YeeunNational NanoFab Center, Division of Nano Convergence Technology Development, REPUBLIC OF KOREA
  3. Park, JongcheolNational NanoFab Center, Division of Nano Convergence Technology Development, REPUBLIC OF KOREA
  4. 서민호교신저자Pusan National University, Department of Information Convergence Engineering, REPUBLIC OF KOREA

초록

Conductive poly-dimethylsiloxane (C-PDMS) composites exhibit a much higher temperature-coefficient-of-resistance (TCR) than metals, making them promising candidates for next-generation temperature sensors [1]. However, polymer-structural changes within PDMS cause time-dependent resistance variation, resulting in signal instability even without temperature fluctuations [2]. Here, we identified residual hydrosilane groups (Si-H) as the origin of such instability and developed a method to eliminate them, enabling long-term stable conductive PDMS micropatterns. As a result, we achieved a resistance-temperature-detector (RTD) with a high TCR of +1.6% /°C with long-term stability. Furthermore, based on this RTD, we developed an ultra-sensitive microfabricated temperature sensor. Specifically, a copper-oxide (CuO) thin film with a negative-temperature-coefficient (NTC) was monolithically integrated with the developed RTD through MEMS-process, operated in a full-bridge Wheatstone configuration. This approach achieved a sensitivity of 16.4 mV/°C in the 25-45°C range, more than 400% higher than conventional RTD-based sensors.

키워드

Conductive polydimethylsiloxane (C-PDMS)copper-oxide (CuO)Full-bridge temperature sensorHigh sensitivityLong-term stabilityNegative Temperature Coefficient (NTC)Resistance Temperature Detector (RTD)Si-H eliminated

식별자

Scopus EID
2-s2.0-105041722898