Preterm Optic Disc Morphology on Handheld OCT and 5-Year Visual Outcomes
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- ESCIScopus
- 저널 순위
- JCR Q1Scopus Q1
- 저널
- OPHTHALMOLOGY SCIENCE6(7) · 2026
- 피인용
- Scopus 0
- FWCI (Scopus)
- 0
- JCR IF
- JCR 2024 4.6
- ISSN
- 2666-9145
저자
- Guillen, Rodrigo제1저자University of Washington School of Medicine, Seattle, WA, USA.
- Alomar, Zahraa OmarUniversity of Washington School of Medicine, Seattle, WA, USA.
- 전혜신Pusan National University, Busan, South Korea.
- Ding, LeonaDepartment of Ophthalmology, University of Washington, Seattle, WA, USA.
- Park, ClaireDepartment of Ophthalmology, University of Washington, Seattle, WA, USA.
- Bunk, JasonDepartment of Ophthalmology, University of Washington, Seattle, WA, USA.
- Grant, LauraMillman-Derr, Rochester Hills, MI, USA.
- Shariff, AyeshaBaylor Scott and White Clinic, Georgetown, TX, USA.
- Gillette, Thomas B.Southwest Eyecare, Albuquerque, NM, USA.
- Legocki, AlexDepartment of Ophthalmology, University of Washington, Seattle, WA, USA.
- Tarczy-Hornoch, KristinaDepartment of Ophthalmology, University of Washington, Seattle, WA, USA.
- Cabrera, Michelle T.교신저자Department of Ophthalmology, University of Washington, Seattle, WA, USA.
초록
Purpose: To determine whether neonatal optic disc morphology measured with handheld spectral-domain OCT (SD-OCT) predicts long-term visual acuity (VA) and refractive outcomes in premature infants. Design: Secondary retrospective analysis of an observational study. Subjects: Premature infants undergoing routine retinopathy of prematurity screening at a tertiary neonatal intensive care unit. Methods: Handheld SD-OCT was performed at approximately 36 weeks’ postmenstrual age (PMA). A semiautomated algorithm quantified optic disc diameter, cup depth, and cup-to-disc ratio (CDR). Visual acuity and cycloplegic refraction were assessed at 9 months, 2 years, and 5 years. Main Outcome Measures: Visual acuity and spherical equivalent (SE) at 9 months, 2 years, and 5 years. Results: The study included 132 eyes from 66 premature infants. The mean disc diameter at 36 weeks’ PMA was 1829 ± 270 μm, cup depth 517 ± 382 μm, and CDR 0.50 ± 0.24. The mean logarithm of the minimum angle of resolution VA was 0.69 ± 0.18 at 9 months, 0.65 ± 0.17 at 2 years, and 0.10 ± 0.15 at 5 years. The mean SE was 1.68 ± 1.54 diopters (D), 0.82 ± 1.87 D, and 0.58 ± 1.30 D, respectively. Optic disc metrics were not associated with VA or SEs at 9 months (n = 52 eyes) or 2 years (n = 39; P > 0.18). They did not predict VA at 5 years (n = 23; P > 0.37). At 5 years, however, greater neonatal cup depth and higher CDR were significantly associated with increased hyperopia (n = 27; P = 0.006 and P = 0.02, respectively), while disc diameter was not. Neonatal sepsis and intraventricular hemorrhage independently predicted poorer VA at 5 years (P = 0.04 and P = 0.001, respectively). Conclusions: Acknowledging a high lost to follow-up rate, neonatal optic disc morphology was not predictive of VA outcomes but was associated with refractive development, with deeper cups and larger CDRs linked to greater hyperopia at 5 years. These findings suggest novel biomarkers for refractive development in the preterm population that deserve further exploration. Financial Disclosure(s): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.
키워드
Cup-to-disc ratioPremature infantsRefractive errorSpectral-domain OCTVisual acuity
식별자
- Scopus EID
- 2-s2.0-105041548076



로그인
연구물 목록으로