본문 바로가기

Preliminary in Vitro Study on an RFID-Tagged Gauze Detection System to Prevent Retention During Laparoscopic Procedures

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q3Scopus Q2
피인용
Web of Science 0Scopus 0
FWCI (Scopus)
0
JCR IF
JCR 2024 1.6
ISSN
1553-3506

저자

  1. 박재균제1저자Pusan Natl Univ Hosp, Sch Med, Dept Surg, Div Gastrointestinal Surg, Busan, South Korea
  2. 주환이Pusan Natl Univ, Sch Mech Engn, Busan, South Korea
  3. 김대환Pusan Natl Univ Hosp, Sch Med, Dept Surg, Div Gastrointestinal Surg, Busan, South Korea
  4. 전태용Pusan Natl Univ Hosp, Sch Med, Dept Surg, Div Gastrointestinal Surg, Busan, South Korea
  5. 안석영교신저자Pusan Natl Univ, Sch Mech Engn, Busan, South Korea
  6. 최창인교신저자Pusan Natl Univ Hosp, Sch Med, Dept Surg, Div Gastrointestinal Surg, Busan, South Korea

초록

Background Retained surgical items (RSIs) represent a significant patient safety concern in minimally invasive surgery (MIS) due to the limitations of conventional detection methods. This study evaluated the technical feasibility of a novel triple-detector radiofrequency identification (RFID) system integrated into a laparoscopic port for automated, real-time tracking and directional differentiation of surgical gauze during procedures. Methods We developed a prototype system integrating three RFID detectors (134.2 kHz) longitudinally into a standard 12-mm laparoscopic port. In a controlled laboratory setting, 118 pieces of RFID-tagged gauze were systematically inserted and retrieved through the port, generating 236 events. The study evaluated detection accuracy across outer, middle, and inner channels, alongside directional discrimination capability and temporal tracking performance using a laparoscopic training model. Results Detection rates exceeded 99% across all three channels (99.58% for the outer channel and 99.15% for middle and inner channels). Directional differentiation accuracy, based on sequential detection patterns, was 94.92% for insertion and 95.76% for removal. Anomalous patterns (4-5%), such as channel omission or duplicate detection, were observed due to passage speed or angle, but they did not impact the final determination of gauze presence or absence. Conclusions This proof-of-concept study demonstrates that an RFID-integrated laparoscopic port can achieve high detection (>99%) and directional accuracy (similar to 95%). These findings support its technical feasibility as an automated safety mechanism for potentially reducing the risk of RSIs in laparoscopic surgery; however, further validation through animal studies and clinical trials is required to confirm these results.

키워드

retained surgical itemsRFIDsurgical gauzelaparoscopySPONGES

식별자

Scopus EID
2-s2.0-105042172582
WoS UID
001794537800001