본문 바로가기

Spatially Adaptive Arch-Cantilever Hybridized Triboelectric Nanogenerator for Self-Powered Sensing in AI-Enhanced Wireless Arrhythmia Monitoring

문서 유형
연구출판물 · 학술지 논문
등재
Nature IndexSCIEScopus
저널 순위
JCR Q1Scopus Q1
저널
ADVANCED FUNCTIONAL MATERIALS36(64) · 2026
피인용
Web of Science 2Scopus 2
FWCI (Scopus)
1.62
JCR IF
JCR 2024 19
ISSN
1616-301X

저자

  1. Cho, Hyunwoo제1저자Kyung Hee Univ, Dept Elect & Informat Convergence Engn, Yongin, South Korea
  2. Yun, JonghyeonKyung Hee Univ, Dept Elect & Informat Convergence Engn, Yongin, South Korea
  3. 고태식Pusan Natl Univ, Pusan Natl Univ Hosp, Sch Med, Dept Orthoped Surg, Pusan, South Korea
  4. 이정섭교신저자Pusan Natl Univ, Pusan Natl Univ Hosp, Sch Med, Dept Orthoped Surg, Pusan, South Korea
  5. Kim, Daewon교신저자Kyung Hee Univ, Dept Elect Engn, Yongin, South Korea

초록

In contemporary healthcare paradigms, heart rate sensors are essential for monitoring cardiac rhythms and facilitating immediate responses during emergencies. Conventional wearable sensors present challenges regarding inaccuracy and inconvenience, whereas implantable sensors encounter energy constraints. To address these limitations, a self-powered implantable triboelectric nanogenerator (iTENG) is proposed as a real-time heart rate sensor integrated into a wireless arrhythmia diagnosis system. The proposed iTENG exhibits highly precise frequency-sensing capability and a spontaneous spatial inducing structure. These features render it particularly suitable for continuous heart rate monitoring in implantable biomedical systems. An arch-cantilever hybridized structure and nanospike-structured zinc ferrite (ZnFe2O4) are employed in the iTENG to enhance in vivo energy harvesting. The arch-cantilever hybridization increases output power by 2.5 times compared to the arch-only structure. Separately, the incorporation of ZnFe2O4 results in a 105.8% elevation in open-circuit voltage (V OC) and a 110.6% augmentation in short-circuit current (I SC) compared to the pristine material. Furthermore, a power management circuit enables a 4.55 & times; voltage reduction and a 176 & times; current increase in the iTENG. The iTENG-based system utilizes K-means clustering for accurate cardiac monitoring and arrhythmia diagnosis, achieving a limit of detection of 0.005 Hz and a 1.36% error rate at 0.1 Hz frequency resolution.

키워드

implantable heart rate sensorspontaneous spatial inducingtriboelectric nanogeneratorwireless arrhythmia diagnosis systemzinc ferrite nanospikesMAXIMAL HEART-RATE

식별자

Scopus EID
2-s2.0-105038535117
WoS UID
001760976400001