본문 바로가기

Wash-Free Digital Detection of Tumor Extracellular Vesicles via Plasmonic Droplet Microfluidics

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q1Scopus Q1
저널
ACS SENSORS11(5) · pp.3676 · 2026
피인용
Web of Science 1Scopus 0
FWCI (Scopus)
0
JCR IF
JCR 2024 9.1
ISSN
2379-3694

저자

  1. Jung, Na Kyung제1저자Ulsan Natl Inst Sci & Technol UNIST, Dept Biomed Engn, Ulsan 44919, South Korea
  2. Karmacharya, MamataUlsan Natl Inst Sci & Technol UNIST, Dept Biomed Engn, Ulsan 44919, South Korea
  3. Choi, HyunminUlsan Natl Inst Sci & Technol UNIST, Dept Biomed Engn, Ulsan 44919, South Korea
  4. 하홍구Pusan Natl Univ, Pusan Natl Univ Hosp, Dept Urol, Sch Med, Busan 49241, South Korea
  5. Oh, In-JaeChonnam Natl Univ, Dept Internal Med, Med Sch, Hwasun 58128, Jeollanamdo, South Korea
  6. 김미현Pusan Natl Univ, Sch Med, Dept Internal Med, 179 Gudeok Ro, Pusan 49241, South Korea
  7. Ryu, Jeong-SeonInha Univ, Inha Univ Hosp, Ctr Lung Canc, Dept Pulmonol,Coll Med, 27 Inhang Ro, Incheon 22322, South Korea
  8. Lim, Chwee TeckNatl Univ Singapore, Inst Hlth Innovat & Technol, Singapore 117599, Singapore
  9. Kumar, Sumit교신저자Ulsan Natl Inst Sci & Technol UNIST, Dept Biomed Engn, Ulsan 44919, South Korea
  10. Cho, Yoon-Kyoung교신저자Ulsan Natl Inst Sci & Technol UNIST, Dept Biomed Engn, Ulsan 44919, South Korea

초록

Early detection of tumor-derived extracellular vesicles (EVs) enables noninvasive cancer diagnostics, but current assays often require wash steps and suffer from limited sensitivity. Here, we developed PlasDroplex, a wash-free digital plasmonic assay that detects tumor-derived extracellular vesicles via droplet-confined binding between EVs and antibody-functionalized gold nanoparticles (Ab-AuNPs), eliminating washing and multistep labeling processes. Plasma (10 μL) is coencapsulated with Ab−AuNPs targeting CD9, EpCAM, PSA, PSMA, and PD-L1 in picoliter droplets. Target binding induces AuNP clustering into plasmonic networks that generate bright “On” droplets, while “Off” droplets remain dark, enabling a wash-free optical readout within 1 h. Limits of detection were 2500−6700 EVs/mL with high reproducibility (CV < 3%). In 63 clinical samples, PSA- and PSMA-positive EVs yielded AUCs of 0.926 and 0.932 for prostate cancer, respectively, while PD-L1 EVs achieved an AUC of 0.998 for lung cancer. PlasDroplex enables rapid, marker-specific, digital droplet-based EV profiling from minimal plasma volumes.

키워드

digital cancer diagnosticsdroplet microfluidicsextracellular vesicleliquid biopsyplasmonic nanoparticles

식별자

Scopus EID
2-s2.0-105036428687
WoS UID
001779223000001