Wash-Free Digital Detection of Tumor Extracellular Vesicles via Plasmonic Droplet Microfluidics
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q1Scopus Q1
- 저널
- ACS SENSORS11(5) · pp.3676 · 2026
- 피인용
- Web of Science 1Scopus 0
- FWCI (Scopus)
- 0
- JCR IF
- JCR 2024 9.1
- ISSN
- 2379-3694
저자
- Jung, Na Kyung제1저자Ulsan Natl Inst Sci & Technol UNIST, Dept Biomed Engn, Ulsan 44919, South Korea
- Karmacharya, MamataUlsan Natl Inst Sci & Technol UNIST, Dept Biomed Engn, Ulsan 44919, South Korea
- Choi, HyunminUlsan Natl Inst Sci & Technol UNIST, Dept Biomed Engn, Ulsan 44919, South Korea
- 하홍구Pusan Natl Univ, Pusan Natl Univ Hosp, Dept Urol, Sch Med, Busan 49241, South Korea
- Oh, In-JaeChonnam Natl Univ, Dept Internal Med, Med Sch, Hwasun 58128, Jeollanamdo, South Korea
- 김미현Pusan Natl Univ, Sch Med, Dept Internal Med, 179 Gudeok Ro, Pusan 49241, South Korea
- Ryu, Jeong-SeonInha Univ, Inha Univ Hosp, Ctr Lung Canc, Dept Pulmonol,Coll Med, 27 Inhang Ro, Incheon 22322, South Korea
- Lim, Chwee TeckNatl Univ Singapore, Inst Hlth Innovat & Technol, Singapore 117599, Singapore
- Kumar, Sumit교신저자Ulsan Natl Inst Sci & Technol UNIST, Dept Biomed Engn, Ulsan 44919, South Korea
- Cho, Yoon-Kyoung교신저자Ulsan Natl Inst Sci & Technol UNIST, Dept Biomed Engn, Ulsan 44919, South Korea
초록
Early detection of tumor-derived extracellular vesicles (EVs) enables noninvasive cancer diagnostics, but current assays often require wash steps and suffer from limited sensitivity. Here, we developed PlasDroplex, a wash-free digital plasmonic assay that detects tumor-derived extracellular vesicles via droplet-confined binding between EVs and antibody-functionalized gold nanoparticles (Ab-AuNPs), eliminating washing and multistep labeling processes. Plasma (10 μL) is coencapsulated with Ab−AuNPs targeting CD9, EpCAM, PSA, PSMA, and PD-L1 in picoliter droplets. Target binding induces AuNP clustering into plasmonic networks that generate bright “On” droplets, while “Off” droplets remain dark, enabling a wash-free optical readout within 1 h. Limits of detection were 2500−6700 EVs/mL with high reproducibility (CV < 3%). In 63 clinical samples, PSA- and PSMA-positive EVs yielded AUCs of 0.926 and 0.932 for prostate cancer, respectively, while PD-L1 EVs achieved an AUC of 0.998 for lung cancer. PlasDroplex enables rapid, marker-specific, digital droplet-based EV profiling from minimal plasma volumes.
키워드
digital cancer diagnosticsdroplet microfluidicsextracellular vesicleliquid biopsyplasmonic nanoparticles
식별자
- Scopus EID
- 2-s2.0-105036428687
- WoS UID
- 001779223000001



로그인
연구물 목록으로