Conformable Microelectrode Arrays Integrated with a Scoop-Shaped Slide-Well for Dynamic Electrophysiological Profiling of Patient-Derived Cardiac Organoids
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q1Scopus Q1
- 저널
- ADVANCED SCIENCE13(31) · 2026
- 피인용
- Web of Science 2Scopus 1
- FWCI (Scopus)
- 1.29
- JCR IF
- JCR 2024 14.1
- ISSN
- 2198-3844
저자
- 김예슬제1저자Pusan Natl Univ, Dept Convergence Stem Cell Res Ctr, Sch Med, Dept Physiol, Yangsan, South Korea
- 정정화Pusan Natl Univ, Sch Transdisciplinary Engn, Dept Cogno Mechatron Engn, Opt & Mechatron Engn Major, Busan, South Korea
- 허경화Pusan Natl Univ, Sch Transdisciplinary Engn, Dept Cogno Mechatron Engn, Opt & Mechatron Engn Major, Busan, South Korea
- 권영우Pusan Natl Univ, Engn Res Ctr Color Modulated Extrasensory Percept, Busan, South Korea
- Lee, JeonghaSeoul Natl Univ, Coll Med, Dept Biomed Sci, Seoul, South Korea
- 정윤지Pusan Natl Univ, Dept Convergence Stem Cell Res Ctr, Sch Med, Dept Physiol, Yangsan, South Korea
- 박규태Pusan Natl Univ, Dept Convergence Stem Cell Res Ctr, Sch Med, Dept Physiol, Yangsan, South Korea
- 정성도Pusan Natl Univ, Res Inst Convergence Biomed Sci & Technol, Yangsan Hosp, Yangsan, South Korea
- 황기원Pusan Natl Univ, Sch Med, Dept Internal Med, Div Cardiol,Yangsan Hosp, Yangsan, South Korea
- Choi, MurimSeoul Natl Univ, Coll Med, Dept Biomed Sci, Seoul, South Korea
- 신진홍Pusan Natl Univ, Coll Med, Dept Neurol, Yangsan Hosp, Yangsan, South Korea
- 홍석원교신저자Pusan Natl Univ, Sch Transdisciplinary Engn, Dept Cogno Mechatron Engn, Opt & Mechatron Engn Major, Busan, South Korea
- 김재호교신저자Pusan Natl Univ, Dept Convergence Stem Cell Res Ctr, Sch Med, Dept Physiol, Yangsan, South Korea
초록
We present an integrated microelectrode array (MEA) platform for high-precision electrophysiological characterization of patient-derived 3D cardiac organoids (COs), enabling dynamic recordings from both healthy and Duchenne muscular dystrophy (DMD) “mini-hearts.” A deformable MEA, fabricated by photolithographic patterning of support layers and microelectrodes, is conformally assembled onto a customized scoop-slide well. The concave geometry enables passive self-alignment of millimeter-scale COs within a multichannel electrode array, allowing simultaneous extracellular field potential (EFP) recording and video-based motion analysis. Using COs derived from human induced pluripotent stem cells of healthy donors and a DMD patient, we resolved region-specific EFP waveforms, which were validated by calcium imaging. DMD COs exhibited severe arrhythmic firing and aberrant waveform morphologies, in contrast to the stable, isochronal rhythms of healthy controls. Single-cell transcriptomic analysis revealed a pathological DMD signature marked by excessive extracellular matrix accumulation and disorganized cardiac architecture, contributing to conduction heterogeneity. Pharmacological challenge with the hERG blocker E-4031 prolonged field potential duration in normal COs but triggered disorganized arrhythmogenic storms in DMD COs. By overcoming the limitations of rigid interfaces and ensuring structural preservation with stable impedance coupling, the presented platform provides a robust biointerface for disease phenotyping, drug screening, and mechanistic interrogation of 3D cardiac tissues.
키워드
cardiac organoidcardiomyopathyduchenne muscular dystrophyelectrophysiologymicroelectrode array
식별자
- Scopus EID
- 2-s2.0-105034578322
- WoS UID
- 001727861900001



로그인
연구물 목록으로