Initial experience of deep learning reconstruction algorithm in lung kernel: clinical usefulness for lung nodules at ultra-low-dose protocol
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q1Scopus Q1
- 저널
- EUROPEAN RADIOLOGY36(7) · pp.5492 · 2026
- 피인용
- Web of Science 0Scopus 0
- FWCI (Scopus)
- 0
- JCR IF
- JCR 2024 4.7
- ISSN
- 0938-7994
저자
- 김재원제1저자Pusan Natl Univ, Pusan Natl Univ Hosp, Sch Med, Dept Radiol, Busan, South Korea
- Kang, ShinhyungGE HealthCare, Seoul, South Korea
- 황민희Pusan Natl Univ, Pusan Natl Univ Hosp, Sch Med, Dept Radiol, Busan, South Korea
- 이지원APusan Natl Univ, Pusan Natl Univ Hosp, Sch Med, Dept Radiol, Busan, South Korea
- 정연주Pusan Natl Univ, Pusan Natl Univ Hosp, Sch Med, Dept Radiol, Busan, South Korea
- 송유선Pusan Natl Univ, Pusan Natl Univ Hosp, Sch Med, Dept Radiol, Busan, South Korea
- 남경진Pusan Natl Univ, Yangsan Hosp, Sch Med, Dept Radiol, Yangsan, South Korea
- 이지원B교신저자Pusan Natl Univ, Pusan Natl Univ Hosp, Sch Med, Dept Radiol, Busan, South Korea
초록
Objectives TrueFidelity (TF), a deep learning image reconstruction algorithm that was originally available only in standard kernel, has recently become available in lung kernel. This is the first study to assess TF in lung kernel (TF Lung) on image quality and nodule sharpness at ultra-low-dose CT (ULD CT). Materials and methods This study included patients who underwent both non-contrast ULD CT and contrast-enhanced CT (CE CT) of the chest. ULD CT scans were reconstructed using 6 algorithms, including Adaptive statistical iterative reconstruction-V in standard kernel (AR50 STD), AR50 in lung kernel (AR50 Lung), TF in standard kernel, and TF Lung at low, medium, and high strengths. CE CT scans were reconstructed using AR50 STD and AR50 Lung. In total, 8 sets of reconstruction images were obtained and reviewed for each patient. Objective image quality, such as image noise, signal-to-noise ratio, and contrast-to-noise ratio, was compared. Nodule sharpness was evaluated by calculating the full-width half-maximum value. Malignancy-related imaging features in nodules that had been pathologically confirmed as malignant were evaluated. CE CT reconstructed in the lung kernel (CE AR50 Lung) served as the reference standard. Results A total of 68 patients underwent analysis. ULD CT reconstructed with TF Lung at all strengths significantly decreased image noise compared to AR50 Lung (all p < 0.001). TF Lung in low and medium strengths showed similar nodule sharpness compared to the reference standard. Conclusion TF Lung has the potential to enhance both image quality and nodule evaluation in ULD CT scans.
키워드
Deep learningSolitary pulmonary noduleMultidetector computed tomographyPULMONARY NODULESIMAGE QUALITYCT
식별자
- Scopus EID
- 2-s2.0-105033471346
- WoS UID
- 001712761900001



로그인
연구물 목록으로