본문 바로가기

파이프랙 부재 단위 모듈화를 위한 패널존 보강요소 삽입 보-기둥 접합부의 구조성능

Structural Performance of Beam-to-Column Connection Implementing Panel Zone Reinforing Elements applicable for Piperack Unit Modularization

문서 유형
연구출판물 · 학술지 논문
등재
KCI
저널 순위
KCI Q4
저널
한국대공간건축 논문집26(1) · pp.17 · 2026
피인용
KCI 0
ISSN
3092-4251

저자

  1. 권예윤제1저자부산대학교
  2. 김보성부산대학교 건축공학과
  3. 강성훈부산대학교
  4. 신동현교신저자부산대학교

초록

In this study, a non-welded beam-to-column connection applicable to the extension and renovation of pipe-rack structures was proposed. The structural performance of the proposed connection was verified at the component level through preliminary finite element analyses. In order to verify structural performance of beam-to-column connection implementing panel zone reinforcing elements, full-scale quasi static test was conducted. As a result, the specimen incorporating box-type panel zone reinfocing element exhivited maximum strength approaximatly 1.3 times higher than that of the specimen with existing connection detail of which structural behavior was governed by weak panel zone deformation. However, the specimen with suggested detail shows stable ductile behavior due to reduction of stress concentrated on the beam-to-column connection since the applied forces were distributed through the yielding of the beam end plate and the reinforcing element inserted into the panel zone.

키워드

Beam-to-Column ConnectionStructural PerformancePanel Zone Reinforcing Elements

식별자

KCI
ART003313971