본문 바로가기

Enhanced detection of bisphenol A with silver-anchored N-doped carbon electrocatalyst

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q1Scopus Q1
저널
APPLIED SURFACE SCIENCE731 · 2026
피인용
Web of Science 1Scopus 1
FWCI (Scopus)
0.85
JCR IF
JCR 2024 6.9
ISSN
0169-4332

저자

  1. Shim, Kyubin제1저자Korea Basic Sci Inst, Strateg Res Ctr Smart Battery, Daejeon 34133, South Korea
  2. 카림 엠디 모바록Pusan Natl Univ, Dept Chem Mat, Busan 46242, South Korea
  3. Park, SungwooKorea Inst Energy Res, Ulsan Adv Energy Technol R&D Ctr, Ulsan 44776, South Korea
  4. Lee, Ho KyungKorea Basic Sci Inst, Strateg Res Ctr Smart Battery, Daejeon 34133, South Korea
  5. 이두용Kyungpook Natl Univ, Dept Phys Educ, Daegu 41566, South Korea
  6. Bae, Jong-SeongKorea Basic Sci Inst, Busan Ctr, Busan 46742, South Korea
  7. 박덕수Pusan Natl Univ, Dept Chem Mat, Busan 46242, South Korea
  8. Kim, Hae Jin교신저자Korea Basic Sci Inst, Strateg Res Ctr Smart Battery, Daejeon 34133, South Korea

초록

To develop an efficient catalyst for bisphenol A (BPA) oxidation and detection, Ag nanoparticle (AgNP) decorated N-doped carbon (NC) composites were prepared by heat treatment of a polymer precursor synthesized through a microwave-assisted hydrothermal process, followed by nitric acid functionalization and subsequent AgNP decoration (Ag@NC). The morphology, chemical composition, and crystalline structure of the carbon composites were characterized using surface analytical methods, which confirmed the uniform dispersion of AgNPs on the N-doped carbon surface with enriched nitrogen functionalities obtained by nitric acid treatment. Electrochemical characterization revealed that Ag@NC exhibited enhanced conductivity, reduced charge-transfer resistance, and superior catalytic activity toward BPA oxidation compared to pristine and N-doped carbon. The sensor fabricated by coating Ag@NC with positively charged polyethylene imine (PEI) (Ag@NC/PEI) demonstrated a wide dynamic range (0.1–1000.0 μM), a low detection limit of 6.3 nM, and excellent reproducibility (RSD ≤ 3.7%). The sensor also exhibited reliable stability, retaining ∼94% of its response current after 30 days of storage. Furthermore, it was selectively detected in the certified reference material and extracted from a polycarbonate (PC) plastic bottle, confirming its practical applicability. These findings demonstrate that the Ag@NC composites are highly promising electrode materials for sensitive, reliable, and practical BPA detection.

키워드

Bisphenol A detectionCarbon nanocompositesElectrochemical oxidationN-doped carbonSilver nanoparticles

식별자

Scopus EID
2-s2.0-105031295076
WoS UID
001706499500001