Enhanced detection of bisphenol A with silver-anchored N-doped carbon electrocatalyst
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q1Scopus Q1
- 저널
- APPLIED SURFACE SCIENCE731 · 2026
- 피인용
- Web of Science 1Scopus 1
- FWCI (Scopus)
- 0.85
- JCR IF
- JCR 2024 6.9
- ISSN
- 0169-4332
저자
- Shim, Kyubin제1저자Korea Basic Sci Inst, Strateg Res Ctr Smart Battery, Daejeon 34133, South Korea
- 카림 엠디 모바록Pusan Natl Univ, Dept Chem Mat, Busan 46242, South Korea
- Park, SungwooKorea Inst Energy Res, Ulsan Adv Energy Technol R&D Ctr, Ulsan 44776, South Korea
- Lee, Ho KyungKorea Basic Sci Inst, Strateg Res Ctr Smart Battery, Daejeon 34133, South Korea
- 이두용Kyungpook Natl Univ, Dept Phys Educ, Daegu 41566, South Korea
- Bae, Jong-SeongKorea Basic Sci Inst, Busan Ctr, Busan 46742, South Korea
- 박덕수Pusan Natl Univ, Dept Chem Mat, Busan 46242, South Korea
- Kim, Hae Jin교신저자Korea Basic Sci Inst, Strateg Res Ctr Smart Battery, Daejeon 34133, South Korea
초록
To develop an efficient catalyst for bisphenol A (BPA) oxidation and detection, Ag nanoparticle (AgNP) decorated N-doped carbon (NC) composites were prepared by heat treatment of a polymer precursor synthesized through a microwave-assisted hydrothermal process, followed by nitric acid functionalization and subsequent AgNP decoration (Ag@NC). The morphology, chemical composition, and crystalline structure of the carbon composites were characterized using surface analytical methods, which confirmed the uniform dispersion of AgNPs on the N-doped carbon surface with enriched nitrogen functionalities obtained by nitric acid treatment. Electrochemical characterization revealed that Ag@NC exhibited enhanced conductivity, reduced charge-transfer resistance, and superior catalytic activity toward BPA oxidation compared to pristine and N-doped carbon. The sensor fabricated by coating Ag@NC with positively charged polyethylene imine (PEI) (Ag@NC/PEI) demonstrated a wide dynamic range (0.1–1000.0 μM), a low detection limit of 6.3 nM, and excellent reproducibility (RSD ≤ 3.7%). The sensor also exhibited reliable stability, retaining ∼94% of its response current after 30 days of storage. Furthermore, it was selectively detected in the certified reference material and extracted from a polycarbonate (PC) plastic bottle, confirming its practical applicability. These findings demonstrate that the Ag@NC composites are highly promising electrode materials for sensitive, reliable, and practical BPA detection.
키워드
Bisphenol A detectionCarbon nanocompositesElectrochemical oxidationN-doped carbonSilver nanoparticles
식별자
- Scopus EID
- 2-s2.0-105031295076
- WoS UID
- 001706499500001



로그인
연구물 목록으로