본문 바로가기

Time-to-vasopressors and clinical outcome by level of diastolic blood pressure and pulse pressure in patients with septic shock: a retrospective analysis of prospective multicenter cohort study

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q1Scopus Q1
저널
CRITICAL CARE30(1) · 2026
피인용
Web of Science 6Scopus 6
FWCI (Scopus)
8.51
JCR IF
JCR 2024 9.3
ISSN
1364-8535

저자

  1. Ko, Ryoung-Eun제1저자Sungkyunkwan Univ, Samsung Med Ctr, Dept Crit Care Med, Dept Med,Sch Med,Div Pulm & Crit Care Med, 81 Irwon Ro, Seoul 06351, South Korea
  2. Kang, DanbeeSamsung Med Ctr, Ctr Clin Epidemiol, Seoul, South Korea
  3. Kim, Won YoungUniv Ulsan, Coll Med, Asan Med Ctr, Dept Emergency Med, Seoul, South Korea
  4. Hyun, Dong-gonUniv Ulsan, Coll Med, Asan Med Ctr, Dept Pulm & Crit Care Med, Seoul, South Korea
  5. Lee, Yeon JooSeoul Natl Univ, Bundang Hosp, Coll Med, Dept Internal Med,Div Pulm & Crit Care Med, Seoul, South Korea
  6. 조우현Pusan Natl Univ, Res Inst Convergence Biomed Sci & Technol, Div Allergy Pulm & Crit Care Med,Dept Internal Med, Transplant Res Ctr,Yangsan Hosp, Yangsan, South Korea
  7. Park, SunghoonHallym Univ, Sacred Heart Hosp, Dept Pulm Allergy & Crit Care Med, Anyang, South Korea
  8. Cho, JuheeSamsung Med Ctr, Ctr Clin Epidemiol, Seoul, South Korea
  9. Suh, Gee Young교신저자Sungkyunkwan Univ, Samsung Med Ctr, Dept Crit Care Med, Dept Med,Sch Med,Div Pulm & Crit Care Med, 81 Irwon Ro, Seoul 06351, South Korea

초록

Background: The optimal timing of vasopressor initiation in septic shock remains uncertain, and mixed trial results may reflect unmeasured hemodynamic heterogeneity. We hypothesized that the association between early norepinephrine and mortality differs by bedside hemodynamic phenotype, as characterized by diastolic blood pressure (DBP) and pulse pressure (PP). Methods: We conducted a retrospective analysis of prospectively collected data from a national sepsis registry (2019–2024). Adults with septic shock presenting to emergency departments were included. Time-to-vasopressor was defined as the time from triage to norepinephrine initiation; restricted cubic splines supported an a priori classification of “early” use as ≤ 25 min. The primary outcome was in-hospital mortality. Patients were stratified by pre-vasopressor DBP (< 50 vs. ≥ 50 mmHg) and, secondarily, by PP (< 25 vs. ≥ 25 mmHg). Multivariable models adjusted for demographics, comorbidities, illness severity (SOFA), three-hour sepsis bundle completion, and mechanical ventilation. Sensitivity analyses explored alternative DBP thresholds (< 40, < 44 mmHg), and subgroup analyses assessed effect consistency. Results: Among 1,104 patients, early norepinephrine was associated with lower mortality only in those with low DBP; there was no mortality benefit when DBP was ≥ 50 mmHg. Mortality associations were stronger at more extreme diastolic hypotension thresholds (< 40 and < 44 mmHg). Hemodynamic phenotyping with PP further refined risk: within the low-DBP group, a wide PP (≥ 25 mmHg) was associated with the most pronounced survival association from immediate vasopressors, whereas a narrow PP showed no clear benefit. Results were directionally consistent across sensitivity and subgroup analyses. Conclusions: The relationship between vasopressor timing and outcomes in septic shock is hemodynamic phenotype dependent. Early norepinephrine appears beneficial when DBP is markedly low, particularly with wide PP, and less critical when DBP is preserved or PP is narrow. Simple bedside measurements (DBP and PP) can guide individualized resuscitation, helping clinicians decide whether to initiate vasopressors or initially emphasize preload or inotropy. Trial registration: Not applicable.

키워드

Diastolic blood pressureNorepinephrinePhenotypePulse pressureSeptic shock

식별자

Scopus EID
2-s2.0-105030584180
WoS UID
001694905000002