Anesthetic management of a patient with recurrent shock caused by anaplastic thyroid carcinoma compressing the internal carotid artery: a case report
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- ESCIKCI
- 저널 순위
- JCR Q3KCI Q3
- 저널
- JOURNAL OF DENTAL ANESTHESIA AND PAIN MEDICINE26(1) · pp.75 · 2026
- 피인용
- KCI 0
- JCR IF
- JCR 2024 1.2
- ISSN
- 2383-9309
저자
- 윤지욱제1저자Department of Anesthesia and Pain Medicine, Pusan National University Yangsan Hospital, Yangsan, Republic of Korea / Department of Anesthesia and Pain Medicine, School of Medicine, Pusan National University, Yangsan, Republic of Korea
- 박순지Department of Anesthesia and Pain Medicine, Daedong Hospital, Busan, Republic of Korea
- 윤정필Department of Anesthesia and Pain Medicine, Pusan National University Yangsan Hospital, Yangsan, Republic of Korea / Department of Anesthesia and Pain Medicine, School of Medicine, Pusan National University, Yangsan, Republic of Korea
- 유영민Department of Anesthesia and Pain Medicine, Pusan National University Yangsan Hospital, Yangsan, Republic of Korea / Department of Anesthesia and Pain Medicine, School of Medicine, Pusan National University, Yangsan, Republic of Korea
- 배재상Department of Anesthesia and Pain Medicine, Pusan National University Yangsan Hospital, Yangsan, Republic of Korea
- 정지은Department of Anesthesia and Pain Medicine, Pusan National University Yangsan Hospital, Yangsan, Republic of Korea
- 김희영교신저자Department of Anesthesia and Pain Medicine, Pusan National University Yangsan Hospital, Yangsan, Republic of Korea / Department of Anesthesia and Pain Medicine, School of Medicine, Pusan National University, Yangsan, Republic of Korea
초록
Stimulation of baroreceptors in the carotid sinus may increase vagal activity and decrease sympathetic activity. In rare cases, this can lead to carotid sinus hypersensitivity, which may cause hypotension, bradycardia, or even asystole. An 86-year-old man scheduled for elective thyroid surgery was admitted to the emergency room with repeated episodes of syncope followed by shock. These episodes were suspected to be caused by metastatic lymph nodes compressing the carotid sinus. In the operating room, a video laryngoscope was used for the first laryngoscopy attempt to minimize neck extension. Endotracheal intubation was successful on the first attempt, and the patient remained hemodynamically stable. Excessive neck extension during laryngoscopy and positioning to optimize the surgical field may trigger carotid sinus hypersensitivity. Therefore, measures to minimize neck extension, including use of video laryngoscopy, and careful monitoring during patient positioning are recommended.
키워드
AnesthesiaCarotid SinusLaryngoscopesShockSyncopeThyroid Neoplasms.