Energy-saving potential of an R600a household refrigerator through mixing with R290 and adjusting compressor revolution speed
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIE
- 저널 순위
- JCR Q1Scopus Q1
- 저널
- CASE STUDIES IN THERMAL ENGINEERING77 · #107549 · 2026
- 피인용
- Web of Science 2
- JCR IF
- JCR 2024 6.4
- ISSN
- 2214-157X
저자
초록
This study experimentally investigated the effects of R600a/R290 blends and compressor speed on the performance of a household refrigerator-freezer (HRF) originally designed for R600a. An experimental apparatus was constructed to simulate a reference HRF, and the performance of the vapor-compression refrigeration system (VCRS) was evaluated using R600a/R290 blends (100/0, 95/5, and 90/10 % by mass) across a range of compressor speed. For comparison, benchmark performance with pure R600a was measured at medium (45 Hz) and high (60 Hz) compressor speeds. Results showed that the 95/5 % blend achieved comparable performance to the pure R600a system at significantly reduced compressor speeds. Specifically, operation at 36-37 Hz matched the performance of the 100/0 % case at 45 Hz, while operation at 47-48 Hz matched the 60 Hz benchmark. The 90/10 % blend achieved equivalent performance to the 60 Hz R600a case at just 38-39 Hz. These reductions in compressor speed led to lower power consumption and notable improvements in coefficient of performance (COP). Compared to the 45 Hz reference case (pure R600a), the 95/5 % blend improved COP by 8-14 %. Against the 60 Hz benchmark case, COP increased by 18-21 % for the 95/5 % blend and by 23-33 % for the 90/10 % blend. Even under elevated condenser outlet temperatures (>= 40 degrees C), the 95/5 % blend resulted in a COP increase of 8.4-10.7 %, demonstrating its potential to enhance the energy efficiency of household refrigerators, particularly in hot climates.
키워드
Household refrigerator-freezerRefrigerant mixtureVariable speed compressorCoefficient of performanceR600aR290MODULATED LINEAR COMPRESSORPERFORMANCE-CHARACTERISTICSSUBCOOLED TEMPERATURESHEAT-EXCHANGERFLOWEFFICIENCYSYSTEMCONFIGURATIONSCONSUMPTIONSIMULATION
식별자
- WoS UID
- 001643108900001



로그인
연구물 목록으로