본문 바로가기

Rotating compensator spectroscopic ellipsometry based on frequency division multiplexing with retardation calibration

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q1Scopus Q1
저널
SCIENTIFIC REPORTS15(1) · #42525 · 2025
피인용
Web of Science 0Scopus 0
FWCI (Scopus)
0
JCR IF
JCR 2024 3.9
ISSN
2045-2322

저자

  1. Park, Jongkyoon제1저자교신저자Korea Res Inst Stand & Sci, Semicond & Display Metrol Grp, 267 Gajeongno, Daejeon 34113, South Korea
  2. 알렉산더 글리세린Pusan Natl Univ, Coll Nanosci & Nanotechnol, Dept Opt & Mechatron Engn, Busan 46241, South Korea
  3. Choi, SukhyunKorea Res Inst Stand & Sci, Semicond & Display Metrol Grp, 267 Gajeongno, Daejeon 34113, South Korea
  4. Cho, Yong JaiKorea Res Inst Stand & Sci, Semicond & Display Metrol Grp, 267 Gajeongno, Daejeon 34113, South Korea
  5. Chegal, Won교신저자Korea Res Inst Stand & Sci, Semicond & Display Metrol Grp, 267 Gajeongno, Daejeon 34113, South Korea

초록

Spectroscopic ellipsometry (SE) is widely used to obtain valuable information about materials such as optical constants or film thickness in a non-destructive way. Various types of SE, each possessing distinct characteristics, have been studied for specific applications. Here, we theoretically and experimentally demonstrate Frequency Division Multiplexing Rotating Compensator Spectroscopic Ellipsometry (FDM-RCSE) by using the frequency division multiplexing (FDM) technique and a rotating compensator with retardation calibration. By utilizing lasers with multiple wavelengths and a spectrally integrating detector, FDM-RCSE enables the simultaneous measurement of three ellipsometry transfer quantities (ETQ) of materials at multiple wavelengths without the need for spectroscopy or switching between wavelengths. This method provides more comprehensive optical material properties such as depolarization and the rotation direction of the elliptical polarization of the measured beam compared to a conventional rotating polarizer ellipsometer. To evaluate the performance of the novel FDM-RCSE technique, the thicknesses of SiO2 films on a Si wafer were measured by determining the ETQ values via FDM-RCSE and compared to a commercially available SE instrument, resulting in a measured thickness difference between both ellipsometers of less than 2 & Aring; on average and high measurement reproducibility. Consequently, it is demonstrated that the FDM technique can be effectively applied to ellipsometry employing compensators with retardation calibration, providing a versatile alternative measurement method in the field of SE.

키워드

TRANSMISSION

식별자

Scopus EID
2-s2.0-105023334736
WoS UID
001628043100038