본문 바로가기

Ultrasonic-mediated novel N,S-co-doped carbon dots-anchored electrochemical platform for the non-invasive detection of diabetes foot ulcer biomarker

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q1Scopus Q1
저널
SURFACES AND INTERFACES77 · #108056 · 2025
피인용
Web of Science 2Scopus 3
FWCI (Scopus)
0.37
JCR IF
JCR 2024 6.3
ISSN
2468-0230

저자

  1. Karthikeyan, R.제1저자Mahendra Coll Engn, Dept Chem, Salem 636106, Tamil Nadu, India
  2. Mani, A.SRM TRP Engn Coll, Ctr Adv Energy Mat, Tiruchirapalli 621105, Tamil Nadu, India
  3. Gowthaman, N. S. K.교신저자SRM TRP Engn Coll, Ctr Adv Energy Mat, Tiruchirapalli 621105, Tamil Nadu, India
  4. 파리스칸 아미르 칸Pusan Natl Univ, Sch Mat Sci & Engn, Busan 46241, South Korea
  5. Sinduja, B.Deemed Univ, Gandhigram Rural Inst, Dept Chem, Gandhigram 624302, Tamil Nadu, India
  6. Kumar, Raju SureshKing Saud Univ, Coll Sci, Dept Chem, POB 2455, Riyadh 11451, Saudi Arabia
  7. Almansour, Abdulrahman I.King Saud Univ, Coll Sci, Dept Chem, POB 2455, Riyadh 11451, Saudi Arabia

초록

This study explored the electrochemical properties of carbon dots (CDs) and their hetero-atom doped systems, nitrogen-doped (-N-CDs) and nitrogen/sulfur co-doped CDs (N,S-CDs) modified glassy carbon (GC) electrode surfaces, focusing on their catalytic oxidation of tyrosine (Tyr). The CDs were synthesized through a basecatalyzed ultrasonication approach with glucose, ammonia and L-cysteine as precursors for CDs, -N-CDs and N,S-CDs, respectively, and thoroughly characterized by various analytical tools. High-resolution transmission electron micrographs revealed mean particle sizes of 1.64, 2.03 and 1.94 nm, respectively for CDs, -N-CDs and N,S-CDs. The as-prepared CDs were immobilized on GC electrodes by direct immersion and different spectroscopic and voltammetric techniques were employed to confirm the modification. The XPS analysis revealed that the CDs are attached directly via it electrons and carboxylate interactions. Electrochemical impedance studies elucidate the heterogeneous rate constant for [Ru(NH3)6]3+/2+ at bare GC, GC/CDs, -N-CDs, and N,S-CDs electrodes as 9.28 x 10-4, 1.71 x 10-3, 2.13 x 10- 3 and 2.96 x 10-3, respectively. The electrodes modified with different CDs were utilized for Tyr detection, among which the N,S-CDs-attached electrode demonstrated superior catalytic performance toward Tyr oxidation by delivering higher oxidation current at less positive oxidation potential, which can be ascribed to the strong it-it and H-it stacking interactions between the phenyl group of Tyr and aromatic domains of N,S-CDs besides the offered larger surface area. Molecular simulation studies confirmed the interaction between N,S-CDs and Tyr. The N,S-CDs-based sensor achieved a high sensitivity of 665.3 mu A mM cm- 1 and a detection limit of 5.1 x 10-10 M in the linear range 50 x 10-9 - 100 x 10-6 M determination of Tyr. Importantly, the sensor was successfully applied for Tyr quantification in human saliva, sweat, blood serum and wound fluid samples, validating its practicability for non-invasive electrochemical monitoring of biomarkers associated with diabetic foot ulcer.

키워드

Nitrogensulphur co-doped carbon dotsUltrasonication synthesisMaillard reaction mechanismTyrosine detectionDiabetic foot ulcer biomarkerNon-invasive electrochemical sensorFLUORESCENT NSENSITIVITYFABRICATIONGRAPHENETYROSINEFACILE

식별자

Scopus EID
2-s2.0-105021842389
WoS UID
001622151500002