본문 바로가기

WIND TUNNEL MEASUREMENTS OF FLOW CHARACTERISTICS USING AN ULTRASONIC WIND ANEMOMETER, INFLUENCED BY THE PASSIVE VORTEX GENERATOR AND BLOCKAGE FROM CIRCULAR OBSTACLES

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q4Scopus Q3
저널
INTERNATIONAL JOURNAL OF MARITIME ENGINEERING167(A3(S)) · pp.A1 · 2025
피인용
Web of Science 0Scopus 0
FWCI (Scopus)
0
JCR IF
JCR 2024 0.6
ISSN
1479-8751

저자

  1. 조욱진제1저자Pusan Natl Univ, Sch Mech Engn, 2,Busandaehak Ro 63beon Gil, Busan 46241, South Korea
  2. 모함마디카라치아라쉬Pusan Natl Univ, Sch Mech Engn, 2,Busandaehak Ro 63beon Gil, Busan 46241, South Korea
  3. 응웬당두이Pusan Natl Univ, Sch Mech Engn, 2,Busandaehak Ro 63beon Gil, Busan 46241, South Korea
  4. 임희창교신저자Pusan Natl Univ, Sch Mech Engn, 2,Busandaehak Ro 63beon Gil, Busan 46241, South Korea

초록

This study investigates wind tunnel experiments on flow characteristics assessed by an ultrasonic wind anemometer under varying upstream conditions. The impact of four circular cylinders arranged in a diamond pattern, simulating a virtual lattice wind mast, with a passive vortex generator at the entrance of the wind tunnel, is examined. Measurements were taken at wind speeds of 5 m/s and 10 m/s, with windward angles of 45, 135, 180, 225, and 315 degrees, to assess their impact on turbulence intensity and gust characteristics. The results indicate that both the circular cylinders and the vortex generator markedly enhance turbulence intensity, with the arrangement of the cylinders producing the most significant impacts. The examination of the Probability Density Function (PDF) for turbulence intensity and gust factor indicates minimal variability and low standard deviations in the base condition. Nevertheless, the diamond-configured cylinders result in an expanded PDF distribution, especially with the lateral turbulence component. The vortex generator, by contrast, induces a more regulated increase in turbulence, exhibiting smaller standard deviations compared to the circular obstacles. The investigation of peak factor and cumulative power spectral density further highlights these effects. In the base case measurements, peak factors are generally concentrated around 1, while cylinder obstruction decreases peak factor values. Cumulative power spectrum density analysis reveals decreased energy levels in the base scenario, whereas the vortex generator elevates spectral density across several frequencies, indicating increased turbulence effects.

키워드

circular cylinder arraypower spectral densityTurbulence intensityultrasonic wind anemometervortex generator

식별자

Scopus EID
2-s2.0-105020258712
WoS UID
001667769400009