본문 바로가기

An open-source compact stimulator for various transcranial and transcutaneous electrical stimulation in preclinical research

문서 유형
연구출판물 · 학술지 논문
등재
KCISCIEScopus
저널 순위
JCR Q3Scopus Q2KCI Q4
저널
Biomedical Engineering Letters (BMEL)16(2) · pp.473 · 2026
피인용
Web of Science 0Scopus 0
FWCI (Scopus)
0
JCR IF
JCR 2024 2.8
ISSN
2093-9868

저자

  1. 매나 폰세카 다니엘 움베르토제1저자Pusan Natl Univ, Dept Informat Convergence Engn, Yangsan 50612, South Korea
  2. 노한나Pusan Natl Univ, Dept Informat Convergence Engn, Yangsan 50612, South Korea
  3. 이동현Pusan Natl Univ, Sch Mech Engn, Pusan 46241, South Korea
  4. 신용일Pusan Natl Univ, Yangsan Hosp, Res Inst Convergence Biomed Sci & Technol, Yangsan 50612, South Korea
  5. 신병철Pusan Natl Univ, Sch Korean Med, Div Clin Med, Yangsan 50612, South Korea
  6. 정준수교신저자Pusan Natl Univ, Sch Mech Engn, Pusan 46241, South Korea

초록

While various transcranial electrical stimulation (tES) and transcutaneous electrical nerve stimulation (TENS) devices differ in target area, pulse parameters, and electrode types, they share the fundamental requirement of generating controlled current pulses. However, existing current stimulators are often expensive and limited in their ability to customize a wide range of pulse parameters, especially for preclinical research involving diverse stimulation protocols. Developing a custom stimulator may not be feasible depending on the technical expertise of the researchers. This study proposes an open-source, compact, and easy-to-make current stimulator built using only commercial off-the-shelf components. The design supports a wide range of stimulation parameters without requiring specialized knowledge in electronics. The prototype stimulator has a form factor of 33 mm x 43 mm x 20 mm and is compatible with general electrode types. Pulse parameters can be simply adjusted by using a knob or tuning resistors and capacitors, enabling simple customization by researchers for varying transcranial and transcutaneous stimulations. The wide tunability in current intensity (2 mu A to 10 mA), pulse rate (0.1 Hz to 100 kHz), and pulse width (10 mu s to DC) is demonstrated, followed by statistical analysis of output waveforms to demonstrate the accuracy and stability of pulse parameters using both high- and low-tolerances components. The results indicate an average accuracy exceeding 96.4% and a coefficient of variance less than 0.57%, suggesting the reliable and robust generation of stimulation waveforms for various tES and TENS applications in preclinical research.

키워드

Compact stimulatorTranscranial electrical stimulationTranscutaneous electrical nerve stimulationUniversal stimulatorELECTROACUPUNCTURE

식별자

Scopus EID
2-s2.0-105022055921
WoS UID
001615677100001