본문 바로가기

Electrochemical Immunosensor Employing a Potential-Guiding, Kinetically Robust, and Counterbalancing Redox Mediator in a Two-Electrode Configuration

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q1Scopus Q1
저널
ACS SENSORS10(11) · pp.8917 · 2025
피인용
Web of Science 4Scopus 5
FWCI (Scopus)
0.87
JCR IF
JCR 2024 9.1
ISSN
2379-3694

저자

  1. 박선화제1저자Pusan Natl Univ, Dept Chem, Busan 46241, South Korea
  2. 김지현Pusan Natl Univ, Dept Chem, Busan 46241, South Korea
  3. 박수빈Pusan Natl Univ, Dept Chem, Busan 46241, South Korea
  4. 김영석Pusan Natl Univ, Dept Chem, Busan 46241, South Korea
  5. 양해식교신저자Pusan Natl Univ, Dept Chem, Busan 46241, South Korea

초록

Electrochemical immunosensors offer rapid, sensitive biomarker detection but typically rely on complex three- or two-electrode architectures with dedicated reference electrodes, complicating fabrication and miniaturization. Herein, we present an electrochemical immunosensor based on a diffusion-isolated, two-electrode system of micropatterned indium tin oxide (ITO) that eliminates the need for a separate reference electrode. A kinetically robust (fast, surface-insensitive) redox mediator [Os(bpy)2Cl2 +/Os(bpy)2Cl2 (OsIII/OsII)] simultaneously acts as the enzymatic substrate, the counterbalancing electroactive species, and the potential-guiding element, removing the requirement for additional electroactive species. Further, diaphorase (DI) is employed as the catalytic label in a sandwich-type immunosensor for prostate-specific antigen (PSA), rapidly reducing OsIII to OsII in the presence of reduced nicotinamide adenine dinucleotide (NADH), enabling efficient electrochemical-enzymatic redox cycling involving the ITO electrode, OsIII, DI, and NADH. By patterning the working and auxiliary electrodes 1.0 mm apart, we achieved diffusion isolation that prevents cross-talk between electrodes. After optimizing blocking, potential difference, and incubation conditions, the sensor achieved a detection limit of approximately 20 pg/mL and a detection range of 20-10 ng/mL in spiked human serum. The results of our analysis of clinical serum samples correlated closely with those of a commercial PSA assay, demonstrating both analytical accuracy and robustness. This study establishes a streamlined, point-of-care-compatible platform that achieves stable potential control and robust kinetics without a dedicated reference electrode.

키워드

two-electrode systemcounterbalancing reactionelectrochemical immunosensorreference electrodeprostate-specific antigenSURFACEARRAY

식별자

Scopus EID
2-s2.0-105023446634
WoS UID
001611249500001