Development and validation of a portable TDLAS system for gas chromatography-level quantification of methane emissions from rice
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- KCISCIEScopus
- 저널 순위
- JCR Q3Scopus Q2KCI Q4
- 저널
- PLANT BIOTECHNOLOGY REPORTS19(6) · pp.789 · 2025
- 피인용
- Web of Science 1Scopus 1KCI 0
- FWCI (Scopus)
- 0.26
- JCR IF
- JCR 2024 1.6
- ISSN
- 1863-5466
저자
- Rajendran, Sujeevan제1저자Wonkwang Univ, Dept Hort Ind, Iksan 54538, South Korea
- Lee, WonbokSeoul Natl Univ, Dept Agr Biotechnol, Seoul 08826, South Korea
- Lee, Sun HwaWonkwang Univ, Dept Hort Ind, Iksan 54538, South Korea
- Shin, DongjinNatl Inst Crop Sci NICS, Dept Southern Area Crop Sci, RDA, Miryang 50463, South Korea
- Jung, Da HeeWonkwang Univ, Dept Hort Ind, Iksan 54538, South Korea
- 강유미Pusan Natl Univ, Dept Hort Biosci, Miryang 50463, South Korea
- Yun, Seok-inWonkwang Univ, Dept Life & Environm Sci, 460 Iksan Daero, Jeonbuk 54583, South Korea
- 제병일Pusan Natl Univ, Dept Hort Biosci, Miryang 50463, South Korea
- Kim, Chul Min교신저자Wonkwang Univ, Dept Hort Ind, Iksan 54538, South Korea
- Song, Young Hun교신저자Seoul Natl Univ, Dept Agr Biotechnol, Seoul 08826, South Korea
초록
Rice cultivation is a significant source of agricultural methane (CH4), yet routine quantification still relies heavily on gas chromatography (GC), which limits throughput and field deployment. Here, we evaluated a portable tunable-diode-laser absorption spectroscopy (TDLAS) detector (PMD) as an alternative to GC for measuring CH4 released from pot-grown rice plants under field conditions. Weekly closed-chamber samples from five cultivars were analyzed in parallel by GC (FID/MS) and the PMD. Standard gas tests showed an excellent linear relationship for the PMD (R2 = 0.9995), indicating a near-ideal response. Across field samples, GC and PMD were strongly associated (R2 = 0.9943). Bland-Altman analysis revealed a mean bias (GC - PMD) of 8.55 with 95% limits of agreement - 9.16 to 26.26, and Lin's concordance correlation coefficient was 0.991, evidencing near-perfect agreement despite a slight systematic offset. A simple calibration with a linear regression eliminated the bias and narrowed the limits of agreement, while preserving the high correlation. Residual analyses suggested a modest influence of CO2 (but not N2O) on between-method differences. Taken together, the PMD provides rapid, robust, and labor-efficient CH4 measurements that closely match GC when a fixed calibration is applied, enabling high-throughput phenotyping of rice genotypes and management practices in both laboratory and field settings. This calibrated, portable approach lowers barriers to large-scale screening for low-emission rice, supporting climate-smart crop improvement.
키워드
MethaneRiceTDLASPortable sensorGas chromatographyBland-Altman
식별자
- Scopus EID
- 2-s2.0-105020805136
- WoS UID
- 001606202200001
- KCI
- ART003272726



로그인
연구물 목록으로