본문 바로가기

Development and validation of a portable TDLAS system for gas chromatography-level quantification of methane emissions from rice

문서 유형
연구출판물 · 학술지 논문
등재
KCISCIEScopus
저널 순위
JCR Q3Scopus Q2KCI Q4
저널
PLANT BIOTECHNOLOGY REPORTS19(6) · pp.789 · 2025
피인용
Web of Science 1Scopus 1KCI 0
FWCI (Scopus)
0.26
JCR IF
JCR 2024 1.6
ISSN
1863-5466

저자

  1. Rajendran, Sujeevan제1저자Wonkwang Univ, Dept Hort Ind, Iksan 54538, South Korea
  2. Lee, WonbokSeoul Natl Univ, Dept Agr Biotechnol, Seoul 08826, South Korea
  3. Lee, Sun HwaWonkwang Univ, Dept Hort Ind, Iksan 54538, South Korea
  4. Shin, DongjinNatl Inst Crop Sci NICS, Dept Southern Area Crop Sci, RDA, Miryang 50463, South Korea
  5. Jung, Da HeeWonkwang Univ, Dept Hort Ind, Iksan 54538, South Korea
  6. 강유미Pusan Natl Univ, Dept Hort Biosci, Miryang 50463, South Korea
  7. Yun, Seok-inWonkwang Univ, Dept Life & Environm Sci, 460 Iksan Daero, Jeonbuk 54583, South Korea
  8. 제병일Pusan Natl Univ, Dept Hort Biosci, Miryang 50463, South Korea
  9. Kim, Chul Min교신저자Wonkwang Univ, Dept Hort Ind, Iksan 54538, South Korea
  10. Song, Young Hun교신저자Seoul Natl Univ, Dept Agr Biotechnol, Seoul 08826, South Korea

초록

Rice cultivation is a significant source of agricultural methane (CH4), yet routine quantification still relies heavily on gas chromatography (GC), which limits throughput and field deployment. Here, we evaluated a portable tunable-diode-laser absorption spectroscopy (TDLAS) detector (PMD) as an alternative to GC for measuring CH4 released from pot-grown rice plants under field conditions. Weekly closed-chamber samples from five cultivars were analyzed in parallel by GC (FID/MS) and the PMD. Standard gas tests showed an excellent linear relationship for the PMD (R2 = 0.9995), indicating a near-ideal response. Across field samples, GC and PMD were strongly associated (R2 = 0.9943). Bland-Altman analysis revealed a mean bias (GC - PMD) of 8.55 with 95% limits of agreement - 9.16 to 26.26, and Lin's concordance correlation coefficient was 0.991, evidencing near-perfect agreement despite a slight systematic offset. A simple calibration with a linear regression eliminated the bias and narrowed the limits of agreement, while preserving the high correlation. Residual analyses suggested a modest influence of CO2 (but not N2O) on between-method differences. Taken together, the PMD provides rapid, robust, and labor-efficient CH4 measurements that closely match GC when a fixed calibration is applied, enabling high-throughput phenotyping of rice genotypes and management practices in both laboratory and field settings. This calibrated, portable approach lowers barriers to large-scale screening for low-emission rice, supporting climate-smart crop improvement.

키워드

MethaneRiceTDLASPortable sensorGas chromatographyBland-Altman

식별자

Scopus EID
2-s2.0-105020805136
WoS UID
001606202200001
KCI
ART003272726