Experimental study on balance drum leakage according to the design parameters of centrifugal high-pressure multistage pumps
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- KCISCIEScopus
- 저널 순위
- JCR Q3Scopus Q2KCI Q4
- 저널
- JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY39(10) · pp.5975 · 2025
- 피인용
- Web of Science 0Scopus 0KCI 0
- FWCI (Scopus)
- 0
- JCR IF
- JCR 2024 1.7
- ISSN
- 1738-494X
저자
초록
This paper presents the effects of clearance, friction coefficient and diameter on the leakage of a balance drum. An experimental pump was set up and the leakage was measured. The experimental results were compared with the leakage predicted by formula suggested by J. F. G & uuml;lich. The experimentally measured leakage flow rate was within 4.0 % of the value predicted by the formula of J. F. G & uuml;lich. Through computational fluid dynamic analysis using the measured inlet and outlet pressures, the prediction showed an error within 2.6 %. Among the design parameters, clearance had the greatest effect on the leakage flow rate. When the clearance was doubled, the leakage flow rate was increased by about 2.8 times. When a shallow groove structure was applied to the annular seal, the leakage flow rate was decreased by 5 %. When the diameter of the balance drum was increased, there was a negligible change in the leakage.
키워드
식별자
- Scopus EID
- 2-s2.0-105018323920
- WoS UID
- 001589231400001
- KCI
- ART003253948



로그인
연구물 목록으로