Electron and proton FLASH beam dosimetry using unified alanine, EBT-XD, and HD-V2 Gafchromic film dosimeters
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q1Scopus Q1
- 저널
- MEDICAL PHYSICS52(10) · #e70022 · 2025
- 피인용
- Web of Science 7Scopus 8
- FWCI (Scopus)
- 2.23
- JCR IF
- JCR 2024 3.2
- ISSN
- 0094-2405
저자
- Jung, Seongmoon제1저자Korea Res Inst Stand & Sci, Ionizing Radiat Metrol Grp, Daejeon, South Korea
- Kim, In JungKorea Res Inst Stand & Sci, Ionizing Radiat Metrol Grp, Daejeon, South Korea
- Yi, Chul-YoungKorea Res Inst Stand & Sci, Ionizing Radiat Metrol Grp, Daejeon, South Korea
- Kim, Yun HoKorea Res Inst Stand & Sci, Ionizing Radiat Metrol Grp, Daejeon, South Korea
- Seong, Young MinKorea Res Inst Stand & Sci, Ionizing Radiat Metrol Grp, Daejeon, South Korea
- Solomon, RukundoKorea Res Inst Stand & Sci, Ionizing Radiat Metrol Grp, Daejeon, South Korea
- Choi, Sang HyounKorea Inst Radiol & Med Sci, Radiat Therapy Technol & Stand, Seoul, South Korea
- Jang, Young-jaeKorea Inst Radiol & Med Sci, Radiat Therapy Technol & Stand, Seoul, South Korea
- Lee, Se ByeongNatl Canc Ctr, Proton Therapy Ctr, Goyang, South Korea
- Kim, Chae-EonNatl Canc Ctr, Proton Therapy Ctr, Goyang, South Korea
- 박상일Pusan Natl Univ, Yangsan Hosp, Dept Radiat Oncol, Yangsan, South Korea
- Park, Jong In교신저자Korea Res Inst Stand & Sci, Ionizing Radiat Metrol Grp, Daejeon, South Korea
초록
Background Ultra-high dose rate (UHDR) radiotherapy, or FLASH RT, has shown potential to spare normal tissues while maintaining tumor control. However, accurate dosimetry at UHDR remains challenging, as conventional ionization chambers suffer from recombination effects. Although radiochromic films and alanine dosimeters have both been investigated independently for FLASH dosimetry, their separate use hinders robust validation and direct comparison of their measurements.Purpose This study aims to develop and evaluate a unified dosimeter containing both alanine and radiochromic film for electron and proton FLASH beam dosimetry. The design allows for simultaneous, co-located irradiation of both dosimeter types, enabling a direct comparison between them. This configuration eliminates confounding factors such as positional offsets, alignment errors, and beam fluctuations, thereby facilitating the validation of measurements and enhancing confidence in FLASH dosimetry.Methods The unified alanine and EBT-XD/HD-V2 film dosimeter was designed with the same outer dimensions as the Advanced Markus chamber (PTW-Freiburg), allowing compatibility with commercial QA phantoms. Alanine and film dosimeters were calibrated under conventional electron and proton beams, traceable to absorbed dose to water from Co-60 gamma rays. The unified dosimeter was used to measure dose from a 9 MeV electron FLASH beam (Varian Clinac iX) and a 230 MeV proton FLASH beam (IBA machine), with alanine and film irradiated simultaneously at the same location.Results The alanine dosimeter measured the dose per pulse, instantaneous dose rate, and mean dose rate at a source-to-surface distance of 100 cm for the electron FLASH beam as 0.99 +/-$ \pm $ 0.02 Gy/pulse, 2.48 x$ \times $ 105 Gy/s, and 357 Gy/s, respectively. The EBT-XD film showed good agreement (within a 2.0% relative difference) in the 10-30-Gy range, whereas the HD-V2 indicated a larger difference (up to 5.9%) compared to the alanine dosimeter. The mean dose rate for the proton FLASH beam, measured by the alanine dosimeter, was 115.4 +/-$\; \pm $ 1.1 Gy/s. The EBT-XD showed a 4.3% relative difference with the alanine dosimeter in the 10-30-Gy range.Conclusions The unified alanine and film dosimeters enabled simultaneous irradiation of the alanine and the films, with combined relative standard uncertainties of 2.4% (k = 1) for the alanine dosimeter and 3.5% (k = 1) for the EBT-XD films at the electron FLASH beam. For the proton FLASH beam, these uncertainties were 3.2% (k = 1) for both the alanine dosimeter and the EBT-XD films. Until dosimetry guidelines for the FLASH RT community are established by a working group such as AAPM TG-359, the dosimetry protocol proposed in this study can serve as a promising approach for FLASH RT facilities worldwide.
키워드
alanine dosimeterEBT-XD filmelectron FLASHHD-V2 filmproton FLASHradiotherapyRELATIVE RESPONSERATE DEPENDENCERAY
식별자
- Scopus EID
- 2-s2.0-105017005100
- WoS UID
- 001580839000001



로그인
연구물 목록으로