Electrical impedance tomography-based temporal signals correlate with quantitative computed tomography-based spatial variables in asthma subjects: a pilot study
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q1Scopus Q1
- 저널
- FRONTIERS IN PHYSIOLOGY16 · #1660948 · 2025
- 피인용
- Web of Science 3Scopus 3
- FWCI (Scopus)
- 0.53
- JCR IF
- JCR 2024 3.4
- ISSN
- 1664-042X
저자
- Jeong, Jinyoung제1저자Kyungpook Natl Univ, Sch Mech Engn, Daegu, South Korea
- 김윤아Pusan Natl Univ, Yangsan Hosp, Res Inst Convergence Biomed Sci & Technol, Yangsan, South Korea
- 이승은Pusan Natl Univ, Yangsan Hosp, Dept Internal Med, Yangsan, South Korea
- 여혜주Pusan Natl Univ, Yangsan Hosp, Dept Internal Med, Yangsan, South Korea
- 허성철교신저자Pusan Natl Univ, Dept Rehabil Med, Yangsan Hosp, Yangsan, South Korea
- Choi, Sanghun교신저자Kyungpook Natl Univ, Sch Mech Engn, Daegu, South Korea
초록
Introduction Quantitative computed tomography (qCT) provides detailed spatial assessments of lung structure and function, while electrical impedance tomography (EIT) offers high temporal resolution for analyzing breathing patterns but lacks structural detail. This study investigates the correlation between qCT-based spatial variables and EIT-based temporal signals to elucidate the physiological relationships between these two modalities.Methods Six participants with asthma underwent pulmonary function tests (PFTs) before and after bronchodilator inhalation. CT scans were obtained in full inhalation and normal exhalation, providing airway hydraulic luminal diameter (D h), airway wall thickness, and percent emphysema, and percent functional small airway disease (fSAD%). On the same day, EIT imaging was performed during tidal breathing, measuring impedance in three different anatomical regions on the chest wall (upper, middle, and lower). The EIT-based impedance was transformed using fast Fourier transform (FFT) to separate perfusion and respiration components including high and low frequencies.Results High-frequency EIT values in the upper lungs were associated with a decline of lung function in pre-bronchodilator. Skewness values, measured by an imbalance between exhalation and inhalation, was elevated in the upper lungs and correlated with impaired lung function. Besides, D h decreased with a higher expiration-to-inspiration (E:I) ratio in the upper lungs and middle lungs. Functionally, higher high frequency values and lower low frequency values in the upper lungs correlated with greater emphysema and functional small airway disease, accompanied by reduced ventilation deformation metrics. Similarly, increased hysteresis variables (e.g., E:I, skewness) in the upper and middle lungs were associated with a further decrease in ventilation deformation metrics.Conclusion EIT temporal signals demonstrated significant associations with spatial metrics from CT images, as well as PFTs metrics. A frequency analysis of EIT may enhance diagnostic approaches and improve understanding of respiratory mechanics in subjects with asthma.
키워드
computed tomographyelectrical impedance tomographyasthmafast fourier transformpulmonary function testsREGIONAL LUNG-FUNCTIONAIR-FLOW OBSTRUCTIONPULMONARY PERFUSIONVIBRATIONIMAGES