본문 바로가기

Skin Pigmentation-Independent Wearable Jaundice Monitoring Based on Dual-path Light-tissue Interaction

문서 유형
연구출판물 · 학술대회 발표논문
등재
Scopus
저널 순위
Scopus Q4
피인용
Scopus 0
FWCI (Scopus)
0
ISSN
0277-786X

저자

  1. Gao, Tengfei제1저자University of California Davis, Department of Electrical and Computer Engineering, 1 Shields Ave, Davis, CA USA 95616-5270;
  2. 김기훈Pusan National University, School of Biomedical Convergence Engineering, 49 Busandaehak-ro, Yangsan, Rep. of Korea 50612;
  3. Han, SengjuUniversity of California Davis, Department of Electrical and Computer Engineering, 1 Shields Ave, Davis, CA USA 95616-5270;
  4. Nguyen, NoahUniversity of California Davis, Department of Electrical and Computer Engineering, 1 Shields Ave, Davis, CA USA 95616-5270;
  5. Ambethkar, Hari RakulUniversity of California Davis, Department of Electrical and Computer Engineering, 1 Shields Ave, Davis, CA USA 95616-5270;
  6. Kong, QishanUniversity of California Davis, Department of Electrical and Computer Engineering, 1 Shields Ave, Davis, CA USA 95616-5270;
  7. Hong, PinhaoUniversity of California Davis, Department of Electrical and Computer Engineering, 1 Shields Ave, Davis, CA USA 95616-5270;
  8. Sidher, AbhijaatUniversity of California, Biomedical Engineering Department, 451 E. Health Sciences Dr., Davis, CA USA 95616-5270;
  9. Jain, AditUniversity of California, Electrical and Computer Engineering Department, 420 Westwood Plaza, Los Angeles, CA 90095;
  10. Truong, JanUniversity of California Davis, Department of Electrical and Computer Engineering, 1 Shields Ave, Davis, CA USA 95616-5270;
  11. 서민호Pusan National University, School of Biomedical Convergence Engineering, 49 Busandaehak-ro, Yangsan, Rep. of Korea 50612;
  12. Jeong, Hyoyoung교신저자University of California Davis, Department of Electrical and Computer Engineering, 1 Shields Ave, Davis, CA USA 95616-5270;

초록

The management of neonatal jaundice is a significant global challenge due to its high prevalence, costly monitoring requirements, and the risk of mortality and permanent impairments. Continuous monitoring is critical for timely treatment; however, current bilirubin meters cannot provide continuous measurements and are often unaffordable in low- and middle-income countries (LMICs). Additionally, these devices have reduced accuracy when used on neonates with darker skin tones. To overcome these limitations, we have developed a wearable jaundice sensor that offers continuous monitoring. This sensor employs transcutaneous optical methods at two wavelengths, with dual light paths specifically designed to minimize interference from skin pigmentation. A human tissue-mimicking phantom was also developed to enhance measurement robustness in scenarios involving high bilirubin concentrations and dark skin tones. The sensor successfully detected both long-path and short-path photoplethysmography (PPG) signals from the finger, capturing absorption data from different tissue depths. Tests conducted on artificial tissues yielded comparable PPG signals, demonstrating the device’s ability to differentiate various degrees of jaundice severity and skin pigmentation.

키워드

bilirubin metercontinuous jaundice monitoringdual light pathlight-tissue interactionskin tonesskin-mimicking phantom

식별자

Scopus EID
2-s2.0-105014512902