초록

Damage to pipelines, which are an important social infrastructure, can cause serious damage to cities. If large relative displacements exceeding the design criteria occur repeatedly due to an earthquake, it can cause damage to the pipe joints. If seismic isolation joints are applied to locations where excessive deformation of the pipe can occur, the seismic performance of the pipe can be improved. Multi-ply metal bellows have excellent performance against low-cycle fatigue loads such as earthquakes. Therefore, multi-ply metal bellows can be used as seismic isolation joints for pipes. In this study, an experimental study was conducted on multi-ply metal bellows, one of the seismic isolation joints. Monotonic and cyclic load tests were performed on two types of multi-ply metal bellows expansion joints to estimate the limit state. The difference in limit performance was analyzed by comparing the failure modes of monotonic and cyclic load tests.