Phase-Locked Time-Stretch Optical Coherence Tomography for Contrast-Enhanced Retinal Microangiography
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q1Scopus Q1
- 저널
- IEEE TRANSACTIONS ON MEDICAL IMAGING44(7) · pp.2906 · 2025
- 피인용
- Web of Science 4Scopus 4
- FWCI (Scopus)
- 0.68
- JCR IF
- JCR 2024 9.8
- ISSN
- 0278-0062
저자
- 김경훈제1저자Pusan Natl Univ, Engn Res Ctr Color Modulated Extrasensory Percept, Busan 46241, South Korea
- 박성진Pusan Natl Univ, Engn Res Ctr Color Modulated Extrasensory Percept, Busan 46241, South Korea
- 김형회Pusan Natl Univ Hosp, Dept Med, Busan 49241, South Korea
- Shin, Jun GeunKorea Photon Technol Inst, Opt Precis Measurement Res Ctr, Gwangju 61007, South Korea
- 엄태중Pusan Natl Univ, Engn Res Ctr Color Modulated Extrasensory Percept, Busan 46241, South Korea
- 김창석교신저자Pusan Natl Univ, Engn Res Ctr Color Modulated Extrasensory Percept, Busan 46241, South Korea
- 이휘돈교신저자Pusan Natl Univ, Engn Res Ctr Color Modulated Extrasensory Percept, Busan 46241, South Korea
초록
Optical coherence tomography angiography has transformed retinal vascular imaging by providing non-invasive, high-resolution visualization. However, achieving an optimal balance between field of view, resolution, and three-dimensional microvasculature contrast, particularly in deeper retinal layers, remains challenging. A phase-locked time-stretch optical coherence tomography microangiography system is developed to address these limitations with a 5-MHz A-line rate and sub-nm phase sensitivity. Utilizing a dual chirped fiber Bragg grating architecture, the swept-source laser achieves an extended coherence length of similar to 10 mm and a 102-nm bandwidth. A time-stretch analog-to-digital converter overcomes the limitations of conventional multi-MHz optical coherence tomography systems, ensuring a 2-mm imaging depth in the air with high spatial resolution. The proposed system enables high-contrast, depth-encoded mapping of key retinal structures, including the superficial and deep capillary plexuses and the choriocapillaris. Compared to a state-of-the-art system, the proposed approach demonstrates enhanced resolution, improved contrast, and faster imaging speeds, enhancing its potential for diagnosing and monitoring retinal and systemic diseases like age-related macular degeneration, diabetic retinopathy, and Alzheimer's disease.
키워드
Optical coherence tomography angiography (OCTA)retinal microvasculaturestretched-pulse active mode-locking (SPML)swept sourceOCT ANGIOGRAPHYSWEPTIMPACTSPEEDCHORIOCAPILLARISPATTERNEYE
식별자
- Scopus EID
- 2-s2.0-105001532366
- WoS UID
- 001523480800025



로그인
연구물 목록으로