본문 바로가기

Advancing thermodynamic efficiency by two-stage flashing mixed refrigerant cycle for hydrogen precooling

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q1Scopus Q1
피인용
Web of Science 7Scopus 7
FWCI (Scopus)
1.14
JCR IF
JCR 2024 6.9
ISSN
1359-4311

저자

  1. 박시환제1저자Pusan Natl Univ, Sch Chem Engn, 2 Busandaehak Ro,63beon gil, Busan 46241, South Korea
  2. 강두호Pusan Natl Univ, Sch Chem Engn, 2 Busandaehak Ro,63beon gil, Busan 46241, South Korea
  3. 김정헌Pusan Natl Univ, Sch Chem Engn, 2 Busandaehak Ro,63beon gil, Busan 46241, South Korea
  4. Jeong, MinseoGS Engn & Construction Corp, Decarbonizat Solut Team, 2477 Nambusunhwan Ro, Seoul 06725, South Korea
  5. Kim, HaksungGS Engn & Construction Corp, Decarbonizat Solut Team, 2477 Nambusunhwan Ro, Seoul 06725, South Korea
  6. Choi, MoonsukGS Engn & Construction Corp, Decarbonizat Solut Team, 2477 Nambusunhwan Ro, Seoul 06725, South Korea
  7. 이인규교신저자Pusan Natl Univ, Sch Chem Engn, 2 Busandaehak Ro,63beon gil, Busan 46241, South Korea

초록

Liquefied hydrogen (LH2) has gained attention as a large-scale storage and transportation option due to its high energy content. At the same time, the energy-intensive characteristics of hydrogen liquefaction remain a significant barrier to the broader implementation of LH2. Previous research has proposed reducing the refrigeration load of the main cooling cycle by introducing a single-loop second precooling cycle. This study suggests using a second precooling based on a flashing mixed refrigerant cycle, where refrigerants are separated according to their temperature ranges. Specifically, dual-pressure second precooling (DPSP) and triple-pressure second precooling (TPSP) are proposed to reduce energy consumption. The proposed processes were optimized through a Bayesian optimization algorithm to minimize the specific energy consumption. Under optimal operating conditions, the specific energy consumption (SEC) of DPSP was 8.204 kWh/kg LH2, and TPSP achieved 8.067 kWh/kg LH2, representing improvements of 8.47 % and 10.00 %, respectively, compared to the base case design. This improvement in energy consumption is directly attributed to the reduction of the main cooling refrigerant flow rate, which stems from the expanded precooling temperature range. Consequently, the exergy efficiencies of the DPSP and TPSP designs reached 38.79 % and 39.27 %, respectively. The results demonstrate that narrowing the main cooling temperature range has a significant impact on improving energy efficiency, which is attributed to the redistribution of refrigeration load. These approaches are key for advancing hydrogen liquefaction technologies and strengthening the sustainability of the liquefied hydrogen-based value chain.

키워드

Flashing mixed refrigerantHydrogen liquefaction processPrecooling cycleProcess optimizationThermodynamic analysisLIQUEFACTION

식별자

Scopus EID
2-s2.0-105008789410
WoS UID
001520513100005