High spectral energy density all-fiber nanosecond pulsed 1.7 μm light source for photoacoustic microscopy
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q1Scopus Q1
- 저널
- PHOTOACOUSTICS44 · 2025
- 피인용
- Web of Science 10Scopus 10
- FWCI (Scopus)
- 1.97
- JCR IF
- JCR 2024 6.8
- ISSN
- 2213-5979
저자
- 박성진제1저자Pusan Natl Univ, Engn Res Ctr Color Modulated Extrasensory Percept, Busan 46241, South Korea
- 박상민Pusan Natl Univ, Engn Res Ctr Color Modulated Extrasensory Percept, Busan 46241, South Korea
- 송유온Pusan Natl Univ, Dept Cognomechatron Engn, Busan 46241, South Korea
- 김지수교신저자Pusan Natl Univ, Engn Res Ctr Color Modulated Extrasensory Percept, Busan 46241, South Korea
- 남태원Pusan Natl Univ, Dept Mat Sci & Engn, Busan 46241, South Korea
- 한동욱Pusan Natl Univ, Dept Cognomechatron Engn, Busan 46241, South Korea
- 김창석Pusan Natl Univ, Engn Res Ctr Color Modulated Extrasensory Percept, Busan 46241, South Korea
- 조순우교신저자Pusan Natl Univ, Engn Res Ctr Color Modulated Extrasensory Percept, Busan 46241, South Korea
- Bouma, Brett E.Harvard Med Sch, Wellman Ctr Photomed, Boston, MA 02114 USA
- 이휘돈교신저자Pusan Natl Univ, Engn Res Ctr Color Modulated Extrasensory Percept, Busan 46241, South Korea
초록
We present a high spectral energy density all-fiber nanosecond pulsed 1.7 μm light source specifically designed for photoacoustic microscopy (PAM). The system targets the 1st overtone absorption of C–H bonds near 1720 nm within the near-infrared-III (NIR-III) window, where lipids exhibit strong optical absorption, and tissues benefit from reduced scattering and high permissible fluence. To achieve narrow-linewidth, high pulse energy, and high pulse repetition rate (PRR), we developed a master oscillator fiber amplifier architecture based on stimulated Raman scattering. A 1589.80 nm Raman pump and a custom-built narrow-linewidth Raman seed laser were employed to generate spectrally pure 1719.44 nm pulses (∼0.10 nm linewidth). The proposed light source delivers nanosecond pulses (∼5 ns) with high pulse energy (≥2.2 μJ) and tunable PRRs up to 300 kHz, resulting in a spectral energy density of approximately 22 μJ/nm—significantly higher than that of conventional 1.7 μm light sources. Performance of the NIR-PAM system was validated through resolution testing with a 1951 USAF target, demonstrating a spatial resolution of approximately 4.14 μm and an axial resolution of approximately 85.5 μm. Phantom imaging of CH2-rich polymer films and ex vivo lipid-rich biological tissues confirmed the system's high spatial fidelity and strong contrast for lipid-specific structures. This compact, stable, and spectrally refined light source with high spectral energy density can offer an effective solution for high-resolution, label-free molecular imaging and represents a promising platform for clinical photoacoustic imaging applications involving lipid detection and metabolic disease diagnostics.
키워드
1.7 µm light sourceAll-fiber nanosecond pulsed light sourceHigh spectral energy densityNarrow-linewidthPhotoacoustic microscopy (PAM)Stimulated Raman scattering (SRS)NARROW-LINEWIDTHDEEP TISSUELASERLIPIDSGAIN
식별자
- Scopus EID
- 2-s2.0-105008539871
- WoS UID
- 001519018500001



로그인
연구물 목록으로