본문 바로가기

High spectral energy density all-fiber nanosecond pulsed 1.7 μm light source for photoacoustic microscopy

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q1Scopus Q1
저널
PHOTOACOUSTICS44 · 2025
피인용
Web of Science 10Scopus 10
FWCI (Scopus)
1.97
JCR IF
JCR 2024 6.8
ISSN
2213-5979

저자

  1. 박성진제1저자Pusan Natl Univ, Engn Res Ctr Color Modulated Extrasensory Percept, Busan 46241, South Korea
  2. 박상민Pusan Natl Univ, Engn Res Ctr Color Modulated Extrasensory Percept, Busan 46241, South Korea
  3. 송유온Pusan Natl Univ, Dept Cognomechatron Engn, Busan 46241, South Korea
  4. 김지수교신저자Pusan Natl Univ, Engn Res Ctr Color Modulated Extrasensory Percept, Busan 46241, South Korea
  5. 남태원Pusan Natl Univ, Dept Mat Sci & Engn, Busan 46241, South Korea
  6. 한동욱Pusan Natl Univ, Dept Cognomechatron Engn, Busan 46241, South Korea
  7. 김창석Pusan Natl Univ, Engn Res Ctr Color Modulated Extrasensory Percept, Busan 46241, South Korea
  8. 조순우교신저자Pusan Natl Univ, Engn Res Ctr Color Modulated Extrasensory Percept, Busan 46241, South Korea
  9. Bouma, Brett E.Harvard Med Sch, Wellman Ctr Photomed, Boston, MA 02114 USA
  10. 이휘돈교신저자Pusan Natl Univ, Engn Res Ctr Color Modulated Extrasensory Percept, Busan 46241, South Korea

초록

We present a high spectral energy density all-fiber nanosecond pulsed 1.7 μm light source specifically designed for photoacoustic microscopy (PAM). The system targets the 1st overtone absorption of C–H bonds near 1720 nm within the near-infrared-III (NIR-III) window, where lipids exhibit strong optical absorption, and tissues benefit from reduced scattering and high permissible fluence. To achieve narrow-linewidth, high pulse energy, and high pulse repetition rate (PRR), we developed a master oscillator fiber amplifier architecture based on stimulated Raman scattering. A 1589.80 nm Raman pump and a custom-built narrow-linewidth Raman seed laser were employed to generate spectrally pure 1719.44 nm pulses (∼0.10 nm linewidth). The proposed light source delivers nanosecond pulses (∼5 ns) with high pulse energy (≥2.2 μJ) and tunable PRRs up to 300 kHz, resulting in a spectral energy density of approximately 22 μJ/nm—significantly higher than that of conventional 1.7 μm light sources. Performance of the NIR-PAM system was validated through resolution testing with a 1951 USAF target, demonstrating a spatial resolution of approximately 4.14 μm and an axial resolution of approximately 85.5 μm. Phantom imaging of CH2-rich polymer films and ex vivo lipid-rich biological tissues confirmed the system's high spatial fidelity and strong contrast for lipid-specific structures. This compact, stable, and spectrally refined light source with high spectral energy density can offer an effective solution for high-resolution, label-free molecular imaging and represents a promising platform for clinical photoacoustic imaging applications involving lipid detection and metabolic disease diagnostics.

키워드

1.7 µm light sourceAll-fiber nanosecond pulsed light sourceHigh spectral energy densityNarrow-linewidthPhotoacoustic microscopy (PAM)Stimulated Raman scattering (SRS)NARROW-LINEWIDTHDEEP TISSUELASERLIPIDSGAIN

식별자

Scopus EID
2-s2.0-105008539871
WoS UID
001519018500001