본문 바로가기

Enhancing the thermodynamic efficiency of hydrogen liquefaction via modifying precooling cycle configuration

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q1Scopus Q1
피인용
Web of Science 9Scopus 10
FWCI (Scopus)
1.73
JCR IF
JCR 2024 6.9
ISSN
1359-4311

저자

  1. 박시환제1저자Pusan Natl Univ, Sch Chem Engn, 2 Busandaehak Ro,63beon Gil, Busan 46241, South Korea
  2. 김정헌Pusan Natl Univ, Sch Chem Engn, 2 Busandaehak Ro,63beon Gil, Busan 46241, South Korea
  3. Jeong, MinseoGS Engn & Construct Corp, Decarbonizat Solut Team, 2477 Nambusunhwan Ro, Seoul 06725, South Korea
  4. Kim, HaksungGS Engn & Construct Corp, Decarbonizat Solut Team, 2477 Nambusunhwan Ro, Seoul 06725, South Korea
  5. Choi, MoonsukGS Engn & Construct Corp, Decarbonizat Solut Team, 2477 Nambusunhwan Ro, Seoul 06725, South Korea
  6. 이인규교신저자Pusan Natl Univ, Sch Chem Engn, 2 Busandaehak Ro,63beon Gil, Busan 46241, South Korea

초록

Hydrogen liquefaction is a cornerstone technology that enables large-scale hydrogen transportation and storage; however, its substantial energy demand remains a significant obstacle to widespread industrial deployment. In mixed refrigerant-based liquefaction processes, the refrigerant composition is perceived as a critical parameter influencing energy efficiency. Especially, increasing the proportion of high-boiling-point components in the refrigerant has been shown to effectively reduce the energy required for compression. Nevertheless, this approach poses challenges related to liquid formation during the compression process, which necessitates effective management solutions. This study investigated two design approaches for addressing liquid-phase management following first flashing for application in a flashing mixed refrigerant cycle: Proposed design 1 employs additional pumping, while Proposed design 2 utilizes direct expansion. Each design was optimized, achieving specific energy consumptions of 8.835 and 8.937 kWh/kg, respectively, corresponding to reductions of 4.47 % and 3.37 % compared to the base case design. Under these conditions, the exergy efficiencies of proposed designs achieved 35.57 % and 35.12 %, respectively. These results demonstrate how the shifting of compression load reduces the precooling energy consumption. As one possible option for improving efficiency, this study contributes to advancing the development of efficient and scalable hydrogen liquefaction technologies.

키워드

Flashing mixed refrigerantHydrogen liquefaction processPrecooling cycleProcess optimizationThermodynamic analysisREFRIGERANTCONVERSIONENERGYOPTIMIZATIONLIQUEFIERSTORAGEEXERGYDESIGN

식별자

Scopus EID
2-s2.0-105007144065
WoS UID
001506883600007