Determination of beam quality correction factors for alanine dosimetry in clinical proton beams
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q2Scopus Q1
- 저널
- PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS134 · #104992 · 2025
- 피인용
- Web of Science 6Scopus 6
- FWCI (Scopus)
- 1.69
- JCR IF
- JCR 2024 2.7
- ISSN
- 1120-1797
저자
- Kim, Chae-Eon제1저자Natl Canc Ctr, Proton Therapy Ctr, 323 Ilsan Ro, Goyang, South Korea
- Park, Jong InKorea Res Inst Stand & Sci, Ionizing Radiat Metrol Grp, 267 Gajeong Ro, Daejoen, South Korea
- Jung, SeongmoonKorea Res Inst Stand & Sci, Ionizing Radiat Metrol Grp, 267 Gajeong Ro, Daejoen, South Korea
- 박상일Pusan Natl Univ, Yangsan Hosp, Yangsan, South Korea
- Jeong, Seonghoon
- An, SeohyeonPohang Accelerator Lab, Pohang, South Korea
- Kim, ChankyuNatl Canc Ctr, Proton Therapy Ctr, 323 Ilsan Ro, Goyang, South Korea
- Jeong, Jong HwiNatl Canc Ctr, Proton Therapy Ctr, 323 Ilsan Ro, Goyang, South Korea
- Kim, HaksooNatl Canc Ctr, Proton Therapy Ctr, 323 Ilsan Ro, Goyang, South Korea
- Lim, Young KyungNatl Canc Ctr, Proton Therapy Ctr, 323 Ilsan Ro, Goyang, South Korea
- Shin, DonghoNatl Canc Ctr, Proton Therapy Ctr, 323 Ilsan Ro, Goyang, South Korea
- Chung, YoonsunHanyang Univ, Dept Nucl Engn, Seoul, South Korea
- Kim, In Jung교신저자Korea Res Inst Stand & Sci, Ionizing Radiat Metrol Grp, 267 Gajeong Ro, Daejoen, South Korea
- Lee, Se Byeong교신저자Natl Canc Ctr, Proton Therapy Ctr, 323 Ilsan Ro, Goyang, South Korea
초록
Introduction: With the advent of FLASH radiotherapy, alanine dosimetry has gained attention as a promising dosimeter owing to its dose-rate independence. However, before utilized in radiotherapy, procedures for determining the absorbed dose to water using alanine under clinical proton beams must be established. This study sought to develop a formula for alanine dosimetry by deriving beam quality correction factors and validating them through Monte Carlo simulations and experimental measurements. Materials and Methods: To calculate the absorbed dose to water using alanine dosimeters, a formula was developed specifically for the plateau region. Alanine dosimeters were irradiated under both a reference beam (Cobalt-60) and clinical proton beams. Beam quality correction factors were calculated and subsequently validated through Monte Carlo simulations using the Tool for Particle Simulation (TOPAS), which is based on GEANT4, as well as through experimental measurements. During the simulations, both crystalline and bulk densities of alanine were considered. Results: The simulation results showed that the average beam quality correction factors for alanine were 1.005 for crystalline density and 1.012 for bulk density. Experimental measurements under clinical proton beams yielded a beam quality correction factor of 1.014, with a standard uncertainty of 2.2%. Conclusions: These results suggest that alanine dosimeters provide reliable and reproducible measurements for proton therapy. The robust methodology demonstrated here highlights the potential of alanine dosimeters in clinical applications, demonstrating their effectiveness and reliability in determining the absorbed dose to water under clinical proton beam conditions.
키워드
VALIDATIONAlanine dosimetryBeam quality correction factorProton therapyTOPAS/GEANT4HIGH-ENERGY PHOTONX-RAYRELATIVE RESPONSEDEPENDENCETG-51
식별자
- Scopus EID
- 2-s2.0-105004598955
- WoS UID
- 001491380700004



로그인
연구물 목록으로