A Combined Index of Steady-State Pattern Electroretinogram and Optical Coherence Tomography Improved the Detection of Early Glaucoma
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q2Scopus Q1
- 저널
- OPHTHALMIC RESEARCH68(1) · pp.252 · 2025
- 피인용
- Web of Science 2Scopus 2
- FWCI (Scopus)
- 0.4
- JCR IF
- JCR 2024 1.9
- ISSN
- 0030-3747
저자
- 김화영제1저자Pusan Natl Univ, Sch Med, Dept Ophthalmol, Pusan Natl Univ Hosp, Busan, South Korea
- 문상우Pusan Natl Univ, Yangsan Hosp, Sch Med, Dept Ophthalmol, Yangsan, South Korea
- 김은아Sungkyunkwan Univ, Samsung Changwon Hosp, Dept Ophthalmol, Sch Med, Chang Won, South Korea
- 김진미Pusan Natl Univ Hosp, Clin Trial Ctr, Biomed Res Inst, Dept Biostat, Busan, South Korea
- 이지웅교신저자Pusan Natl Univ, Sch Med, Dept Ophthalmol, Pusan Natl Univ Hosp, Busan, South Korea
초록
Introduction: The aims of the study were to evaluate the structure-function relationship between steady-state pattern electroretinogram (ssPERG), optical coherence tomography (OCT), and visual field (VF) tests and to investigate indicators that enhance the detection of preperimetric and early-stage primary open-angle glaucoma (POAG). Methods: In this retrospective cohort study, patients with POAG and normal subjects who underwent ssPERG, OCT, and VF tests were included. We defined the ratio of the amplitudes from 0.8 degrees checks to 16 degrees checks as the pattern electroretinogram ratio (PERGratio). The thickness of the macular ganglion cell inner plexiform layer and the circumpapillary retinal nerve fiber layer (cpRNFL) were measured using spectral-domain OCT. We compared the areas under the receiver operating characteristic curves (AUCs) for ssPERG, OCT, and VF test parameters. A combined index using structural and functional measures was generated using logistic regression models to improve diagnostic accuracy. Results: Four parameters had AUCs higher than 0.8; PERGratio (AUC = 0.890), average cpRNFL thickness (AUC = 0.827), 7 o'clock cpRNFL thickness (AUC = 0.844), and inferior quadrant cpRNFL thickness (AUC = 0.830). The new index, which combines the PERGratio and 7 o'clock cpRNFL thickness, significantly improved diagnostic accuracy (AUC = 0.951), outperforming the best four parameters (all p <= 0.004). Furthermore, the combined index of PERGratio and 7 o'clock cpRNFL thickness showed significantly higher diagnostic accuracy compared to those combining the 7 o'clock cpRNFL thickness with VF mean deviation, pattern standard deviation, and VF index. Conclusion: The combined index of ssPERG, indicative of retinal ganglion cell dysfunction, and the OCT test, indicative of focal structural damage, improved the detection of patients with POAG in its early stage.
키워드
Steady-state pattern electroretinogramOptical coherence tomographyPrimary open-angle glaucomaGANGLION-CELL FUNCTIONREPRODUCIBILITYTHICKNESS
식별자
- Scopus EID
- 2-s2.0-105003783628
- WoS UID
- 001478908700001



로그인
연구물 목록으로