본문 바로가기

Studies on the Measurement of Contact Resistance in No-Insulation HTS Coils

문서 유형
연구출판물 · 학술지 논문
등재
ESCIKCIScopus
저널 순위
JCR Q4Scopus Q4KCI Q4
저널
한국초전도.저온논문지27(1) · pp.33 · 2025
피인용
Scopus 1KCI 0
FWCI (Scopus)
0.2
JCR IF
JCR 2024 0.1
ISSN
1229-3008

저자

  1. 조봉현제1저자Department of Electrical and Electronic Engineering, Pusan National University, Busan, Korea
  2. Park, SeongkeonDepartment of Electrical Engineering, Kangwon National University, Chuncheon, Korea
  3. Hahn, GaramPohang Accelerator Laboratory, Pohang University of Science and Technology, Pohang, Korea
  4. Choi, SeyongDepartment of Electrical Engineering, Kangwon National University, Chuncheon, Korea
  5. 이지호교신저자Department of Electrical and Electronic Engineering, Pusan National University, Busan, Korea

초록

Accurate measurement of contact resistance in no-insulation (NI) high-temperature superconducting (HTS) coils is crucial for their performance evaluation. The sudden discharge test is a widely used method for measuring the contact resistance of NI HTS coils. However, there are several issues regarding the data acquisition system (DAQ) during the test. In particular, the DAQ must operate at a sampling rate exceeding 500 S/s. An infinite impulse response (IIR) filter can introduce a phase delay into the filtered signal compared to the original data. For instance, applying a 4-Hz low-pass Butterworth filter to a high-frequency signal may lead to measurement errors due to this delay. Moreover, remnant field induced by the screening current after the current transportation introduces uncertainty of conducting sudden discharge tests. This paper proposes the qualified settings of DAQ system configuration for sudden discharge test and suggests an alternative method for measuring the contact resistance of NI HTS coils.

키워드

contact resistancedata acquisitionscreening current induced magnetic field

식별자

Scopus EID
2-s2.0-105004381111
KCI
ART003194436