본문 바로가기

Effect of discharged pressure for fire extinguishing agent performance (HFC-125) considering fire accident in the aviation

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q2Scopus Q1
저널
FIRE SAFETY JOURNAL153 · 2025
피인용
Web of Science 3Scopus 3
FWCI (Scopus)
0.53
JCR IF
JCR 2024 3.3
ISSN
0379-7112

저자

  1. 김준성제1저자Pusan Natl Univ, Sch Mech Engn, 2 Busandaehak Ro 63 Beon Gil, Busan 46241, South Korea
  2. Ahn, HyeongjinKorea Aerosp Ind LTD 78, Sacheon 52214, Gyeongsangnam D, South Korea
  3. Park, JiwonKorea Aerosp Ind LTD 78, Sacheon 52214, Gyeongsangnam D, South Korea
  4. 송정현Pusan Natl Univ, Sch Mech Engn, 2 Busandaehak Ro 63 Beon Gil, Busan 46241, South Korea
  5. Choi, MinsungGangneung Wonju Natl Univ, Dept Automot Engn, Wonju 26403, Gangwon Do, South Korea
  6. 박원규Pusan Natl Univ, Sch Mech Engn, 2 Busandaehak Ro 63 Beon Gil, Busan 46241, South Korea
  7. 정철웅Pusan Natl Univ, Sch Mech Engn, 2 Busandaehak Ro 63 Beon Gil, Busan 46241, South Korea
  8. 최경민교신저자Pusan Natl Univ, Sch Mech Engn, 2 Busandaehak Ro 63 Beon Gil, Busan 46241, South Korea
  9. 박예슬교신저자Mokpo Natl Univ, Dept Mech Engn, 1666 Yeongsan Ro, Muan Gun 58554, Jeollanam Do, South Korea

초록

HFC-125 (fire extinguishing agent) affects the charged pressure inside the vessel depending on the ambient temperature. Aviation fire extinguishing systems are exposed to ambient temperatures ranging from −50 °C to 200 °C. In this study, experiments were conducted at changing charged pressure, high ambient temperature, and low ambient temperature under the assumption that the pressure inside the vessel changes depending on the ambient temperature. The charged pressure range is 3.61 MPa–4.90 MPa. It was confirmed that as the charged pressure increased, the discharge time decreased from 2.19 s to 1.67 s and pressure recovery occurred. The charged pressure range where pressure recovery occurs was predicted to be 2.63 MPa–5.12 MPa. The pressure recovery showed the largest pressure difference at 4.21 MPa of charged pressure. In the high temperature experiments, the ambient temperatures were 56 °C and 76 °C, and chalked flow occurred above 56 °C. This means that the discharge rate is constant above 56 °C. In low temperature experiments, HFC-125 was lowered to below −30 °C and discharged at −14 °C and −18.8 °C. The low temperature experiment results showed that pressure recovery did not occur at low temperatures due to unsaturation of dissolved nitrogen. Additionally, oscillations also occurred, resulting in discontinuous discharge rate.

키워드

Aircraft fire extinguish systemAmbient temperatureDissolved nitrogenHFC-125Pressure recovery

식별자

Scopus EID
2-s2.0-105000376392
WoS UID
001467144800001