본문 바로가기

Similar wear rates of 1st and 2nd generation highly cross-linked polyethylene in primary total hip arthroplasty in patients less than 30 years of age: A minimum 5-year follow-up

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q2Scopus Q1
피인용
Web of Science 1Scopus 1
FWCI (Scopus)
0.5
JCR IF
JCR 2024 2.2
ISSN
1877-0568

저자

  1. 김정신제1저자Pusan Natl Univ, Sch Med, Dept Orthopaed Surg, Yangsan Hosp, 20 Geumo Ro, Yangsan 626770, Gyeongsangnam D, South Korea
  2. 도민욱Pusan Natl Univ, Sch Med, Dept Orthopaed Surg, Yangsan Hosp, 20 Geumo Ro, Yangsan 626770, Gyeongsangnam D, South Korea
  3. 한정범Pusan Natl Univ, Sch Med, Dept Orthopaed Surg, Yangsan Hosp, 20 Geumo Ro, Yangsan 626770, Gyeongsangnam D, South Korea
  4. 이상민Pusan Natl Univ, Sch Med, Dept Orthopaed Surg, Yangsan Hosp, 20 Geumo Ro, Yangsan 626770, Gyeongsangnam D, South Korea
  5. 문남훈Pusan Natl Univ Hosp, Dept Orthopaed Surg, 179 Gudeok Ro, Busan 49241, South Korea
  6. 서근택Pusan Natl Univ, Sch Med, Dept Orthopaed Surg, Yangsan Hosp, 20 Geumo Ro, Yangsan 626770, Gyeongsangnam D, South Korea
  7. 신원철교신저자Pusan Natl Univ, Sch Med, Dept Orthopaed Surg, Yangsan Hosp, 20 Geumo Ro, Yangsan 626770, Gyeongsangnam D, South Korea

초록

Background: Younger patients who undergo total hip arthroplasty (THA) often exhibit higher activity and functionality. After the 1 st generation highly cross-linked polyethylene liners (HXLPE), there was advancement with the development of the 2nd generation Vitamin E-infused highly cross-linked polyethylene (VEPE) for polyethylene liners. However, there is limited research comparing these advancements, especially in younger patients. Therefore we did a retrospective comparative study aiming to determine: 1) the wear rate, 2) survivorships of the 1 st and 2nd generations of HXLPE in patients aged <30 years who underwent THA. Hypothesis: There is no difference between first and second generation of highly cross-linked polyethylene regarding lower linear and volumetric wear rates. Methods: From 2008–2019, we selected 121 patients, 150 hips of ceramic-polyethylene articulation THA in patients aged <30 years at least 5 years of follow-up. These patients were divided into two groups: 80 hips for 1 st generation HXLPE and 70 hips for 2nd generation VEPE. Both groups had no significant difference regarding age, gender, BMI, and the indication for THA. We compared the wear rate of polyethylene in both groups using PolyWare 7 software and assessed the 5-year THA survival rate. Results: In both groups, there was no significant difference in linear and volumetric wear, as measured using PolyWare 7 software. Linear wear rate was 0.0365 ± 0.0187 mm/yr in the 1 st generation HXLPE and 0.0351 ± 0.0171 mm/yr in the 2nd generation VEPE groups. Volumetric wear rate was 20.848 ± 11.319 mm3/yr in the 1 st generation HXLPE and 18.679 ± 7.933 mm3/yr in the 2nd generation VEPE groups. The overall 5-year survival rate post-surgery was 98.7%; no significant difference in the survival rates between the 1 st and 2nd generation groups (98.8 and 98.6% for the 1 st and 2nd generation groups). Conclusion: In young patients, there was no significant difference in the wear rates between the 1 st generation HXLPE and 2nd generation VEPE when using ceramic-polyethylene bearing surfaces. Based on the analysis of complications, survival rates, and functional scores post-surgery, the results of THA using ceramic-any HXLPE articulation were satisfactory in patients aged <30 years. Level of evidence: III; Case-control study

키워드

Bearing surfacesCeramic-polyethylene articulationHighly cross-linked polyethyleneTotal hip arthroplasty

식별자

Scopus EID
2-s2.0-85216669096
WoS UID
001631753100024