Optimal Indocyanine Green Dosage for Repetitive Angiography for Laparoscopic Colorectal Surgery
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q1Scopus Q1
- 저널
- MEDICINA-LITHUANIA60(12) · #1966 · 2024
- 피인용
- Web of Science 5Scopus 5
- FWCI (Scopus)
- 0.55
- JCR IF
- JCR 2023 2.4
- ISSN
- 1010-660X
저자
- 손경모제1저자교신저자Pusan Natl Univ, Yangsan Hosp, Sch Med, Dept Surg, Yangsan 50612, South Korea
- 박상호Pusan Natl Univ, Dept Elect Engn, Busan 46241, South Korea
- 김남수Pusan Natl Univ, Dept Elect Engn, Busan 46241, South Korea
- 윤미숙Pusan Natl Univ, Yangsan Hosp, Res Inst Convergence Biomed Sci & Technol, Yangsan 50612, South Korea
- 이인영Pusan Natl Univ, Yangsan Hosp, Res Inst Convergence Biomed Sci & Technol, Yangsan 50612, South Korea
- 권명숙Pusan Natl Univ, Yangsan Hosp, Res Inst Convergence Biomed Sci & Technol, Yangsan 50612, South Korea
- 김태균Pusan Natl Univ, Sch Med, Dept Anesthesia & Pain Med, Busan 50612, South Korea
- 이은화Pusan Natl Univ, Yangsan Hosp, Dept Pharm, Yangsan 50612, South Korea
- 황은정Pusan Natl Univ, Yangsan Hosp, Dept Pharm, Yangsan 50612, South Korea
- 백광열Pusan Natl Univ, Dept Elect Engn, Busan 46241, South Korea
초록
Background and Objectives: This study aimed to determine the minimal effective dose of indocyanine green (ICG) required for accurately assessing colonic perfusion during laparoscopic colorectal surgery using a laser-assisted laparoscopic near-infrared (NIR) camera system. Materials and Methods: In 15 patients with colorectal cancer undergoing right hemicolectomy, the left branch of the middle colic artery was preserved, and ICG angiography was performed in the transverse colon. To determine the optimal ICG dose, experimental doses of 0.01, 0.02, 0.03, 0.04, and 0.05 mg of ICG per patient's body weight (kg) were administered intravenously in each group. Additionally, a conventional dose of 0.2 mg/kg was administered in the same patients more than 30 min after the initial dose. For quantitative analysis, the fluorescent expression region was extracted, and fluorescence intensity was analyzed using automatic image processing. Analysis accessibility, T1/2MAX, perfusion time ratio, slope, artificial intelligence (AI)-based perfusion pattern analysis, and washout time were measured in 150 detailed regions of interest in each image. Results: Group 1 (0.01 mg/kg) showed significantly lower accessibility rates for quantitative analysis (48.0%) compared with Groups 2-5 (84.7-100%). The mean slope value in Group 1 was 3.7, which fell below the acceptable threshold (>4) and was significantly lower than that of the other groups (p < 0.001). An acceptable AI-based perfusion pattern was 14.2% in Group 1, significantly lower than in Groups 2-5 (66.4-100%). Washout time was significantly faster with minimal doses compared with conventional doses (39.0 +/- 15.8 s vs. 117.5 +/- 4.9 s, respectively, p < 0.001). Conclusions: This study supports the use of minimal ICG doses, ranging from 0.02 to 0.05 mg/kg, to optimize repetitive ICG angiography using a laser-assisted laparoscopic NIR camera.
키워드
indocyanine greenangiographycolorectal surgerylaparoscopynear-infraredperfusion imagingartificial intelligencePERFUSION ASSESSMENTCLEARANCE ABILITYOUTCOMES
식별자
- Scopus EID
- 2-s2.0-85213733564
- WoS UID
- 001385653200001



로그인
연구물 목록으로