본문 바로가기

Evaluation of different designs of 3D printed clear aligners on mandibular premolar extrusion using force/moment measurement devices and digital image correlation method

문서 유형
연구출판물 · 학술지 논문
등재
KCISCIEScopus
저널 순위
JCR Q1Scopus Q1KCI Q3
저널
KOREAN JOURNAL OF ORTHODONTICS54(6) · pp.359 · 2024
피인용
Web of Science 10Scopus 10KCI 2
FWCI (Scopus)
2.25
JCR IF
JCR 2023 2.6
ISSN
2234-7518

저자

  1. 백종찬제1저자Department of Orthodontics, Dental Research Institute, Pusan National University Dental Hospital, Yangsan, Korea
  2. 최윤경교신저자Department of Orthodontics, Biomedical Research Institute, Pusan National University Hospital, Busan, Korea
  3. 조용훈School of Computer Science and Engineering, Pusan National University, Busan, Korea
  4. 백윤주School of Computer Science and Engineering, Pusan National University, Busan, Korea
  5. 김성훈Department of Orthodontics, Dental Research Institute, Pusan National University Dental Hospital, Yangsan, Korea
  6. 김성식Department of Orthodontics, Dental Research Institute, Pusan National University Dental Hospital, Yangsan, Korea
  7. 박수병Department of Orthodontics, Dental Research Institute, Pusan National University Dental Hospital, Yangsan, Korea
  8. Kim, Ki BeomDepartment of Orthodontics, Saint Louis University, Saint Louis, MO, USA
  9. 김용일Department of Orthodontics, Dental Research Institute, Pusan National University Dental Hospital, Yangsan, Korea

초록

Objective: This study aimed to investigate the effect of three-dimensional (3D) printed clear aligners (CA) with different designs on the extrusion of mandibular premolars using a force/moment measurement system and digital image correlation (DIC). Methods: The forces and moments applied to the mandibular canines, first and second premolars were measured using a multi-axis force/ moment transducer when an extrusion of 0.5 mm was planned, assuming the mandibular first premolars were intruded by 1 mm. In addition, displacement and strain changes in the CA were analyzed using the DIC method. CA designs were categorized based on the presence of first premolar attachment and subdivided into equigingival margins, 1-mm extended margins, equi-margins with 1-mm thickness and height, and equi-margins with 1-mm reduced buccolingual width. The CA was printed directly at a thickness of 0.5 mm, and the experiments were conducted at 37°C. Results: The results showed that attachment played an important role in the extrusion of first premolars in both the force/moment measurement system and the DIC method. Intrusion was observed without attachment, even though extrusion was planned. CA designs apply greater force to the cervical region by extending the margin or reducing the buccolingual width, thereby improving extrusion efficiency. Conclusions: Force and moment changes in direct 3D printed CA are complex and difficult to predict; however, modifying aligner designs, such as extending the margin or reducing buccolingual width, and using appropriate attachments could minimize unwanted tooth movement, optimize planned treatment, and increase treatment predictability.

키워드

AlignersExtrusionForceMoment

식별자

Scopus EID
2-s2.0-85210815502
WoS UID
001408226300001
KCI
ART003137892