Adverse effects of compressor lubricant on household refrigerator-freezer performance and sustainable, feasible remedies
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q1Scopus Q1
- 저널
- RENEWABLE & SUSTAINABLE ENERGY REVIEWS207 · #114967 · 2025
- 피인용
- Web of Science 12Scopus 12
- FWCI (Scopus)
- 0.62
- JCR IF
- JCR 2024 16.3
- ISSN
- 1364-0321
저자
- Ko, Jaedeok제1저자Natl Korea Maritime & Ocean Univ, Div Mech Engn, Busan 49112, South Korea
- 정지환교신저자Pusan Natl Univ, Sch Mech Engn, 2 Busandaehak Ro 63 beon Gil, Busan 46241, South Korea
초록
This study reviews the impact of lubricants on the components and efficiency of household refrigerator-freezers (HRFs). A comprehensive review of the existing literature reveals that lubricants impair overall heat transfer performance within heat exchangers while simultaneously increasing the overall frictional pressure drop. Additionally, the presence of oil disrupts the refrigerant flashing process within the capillary tube and reduces both the cooling capacity and the coefficient of performance of the system. This leads to increased compressor power consumption to achieve the same cooling capacity. Consequently, despite the potential of oil to decrease discharge temperature and mitigate seal leakage losses, it negatively impacts overall system performance. To counter these adverse effects, this study presents three strategies, derived from an extensive review: the use of oil-free compressors, the incorporation of nanoscale additives, and the application of oil separators. The review suggests that nanoscale additives, provided they are uniformly dispersed throughout the refrigerant and oil over a prolonged period, hold promise in enhancing heat transfer performance and mitigating the degradation caused by oil. Oil-free compressors also show considerable potential, though challenges associated with increased noise and reduced lifespan due to the absence of oil remain. The use of oil separators in HRFs is a relatively underinvestigated topic, with fewer studies compared to the other two strategies, indicating the need for further research. This underscores the importance of continued study in this field to optimize the performance and efficiency of HRFs.
키워드
LubricantOilRefrigerant-oil mixtureHousehold refrigerator-freezerRefrigerationBOILING HEAT-TRANSFERPRESSURE-DROP CHARACTERISTICSCONTINUOUS EMPIRICAL CORRELATIONMODULATED LINEAR COMPRESSOROIL CIRCULATION RATEHORIZONTAL SMOOTHTHERMODYNAMIC PROPERTIESTRANSFER COEFFICIENTSR410A-OIL MIXTUREPART I
식별자
- Scopus EID
- 2-s2.0-85205915676
- WoS UID
- 001332929900001



로그인
연구물 목록으로