본문 바로가기

Bidirectional gated recurrent unit network model can generate future visual field with variable number of input elements

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q1Scopus Q1
저널
PLOS ONE19(8) · 2024
피인용
Web of Science 3Scopus 4
FWCI (Scopus)
0.26
JCR IF
JCR 2023 2.9
ISSN
1932-6203

저자

  1. 이주황제1저자교신저자Pusan Natl Univ, Coll Med, Dept Ophthalmol, Busan, South Korea
  2. Park, KeunheungBusan Med Ctr, Busan, South Korea
  3. 김화영Pusan Natl Univ, Coll Med, Dept Ophthalmol, Busan, South Korea
  4. 문상우Pusan Natl Univ, Coll Med, Dept Ophthalmol, Busan, South Korea
  5. Kim, JunglimInje Univ, Coll Med, Busan Paik Hosp, Dept Ophthalmol, Busan, South Korea
  6. Jin, SangwookDong A Univ, Coll Med, Dept Ophthalmol, Busan, South Korea
  7. Lee, SeungukKosin Univ, Coll Med, Dept Ophthalmol, Busan, South Korea
  8. 이지웅교신저자Pusan Natl Univ, Coll Med, Dept Ophthalmol, Busan, South Korea

초록

Purpose This study aimed to predict future visual field tests using a bidirectional gated recurrent unit (Bi-GRU) and assess its performance based on the number of input visual field tests and the prediction time interval. Materials and methods This study included patients who underwent visual field tests at least four times at five university hospitals between June 2004 and April 2022. All data were accessed in October 2022 for research purposes. In total, 23,517 eyes with 185,858 visual field tests were used as the training dataset, and 1,053 eyes with 9,459 visual field tests were used as the test dataset. The Bi-GRU architecture was designed to take a variable number of visual field tests, ranging from 3 to 80, as input and predict visual field tests at the desired arbitrary time point. It generated the mean deviation (MD), pattern standard deviation (PSD), Visual Field Index (VFI), and total deviation value (TDV) for 54 test points. To analyze the model performance, the mean absolute error between the actual and predicted values was calculated and analyzed for glaucoma severity, number of input visual field tests, and prediction time interval. Results The prediction errors of the Bi-GRU model for MD, PSD, VFI, and TDV ranged from 1.20 to 1.68 dB, 0.95 to 1.16 dB, 3.64 to 4.51%, and 2.13 to 2.60 dB, respectively, depending on the number of input visual field tests. Prediction errors tended to increase as the prediction time interval increased; however, the difference was not statistically significant. As the severity of glaucoma worsened, the prediction errors significantly increased. Conclusion In clinical practice, the Bi-GRU model can predict future visual field tests at the desired time points using three or more previous visual field tests.

키워드

GLAUCOMAPROGRESSION

식별자

Scopus EID
2-s2.0-85202506549
WoS UID
001305453900032