곡면형 델타 윙렛 와류 발생기의 혼합 배치에 따른 휜-튜브의 전열 및 유동 특성
Heat Transfer and Flow Characteristics of a Finned-tube according to the Combined Arrangement of Curved Delta Winglet Vortex Generators
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- KCI
- 저널 순위
- KCI Q3
- 저널
- 한국유체기계학회 논문집27(3) · pp.28 · 2024
- 피인용
- KCI 0
- ISSN
- 2287-9706
저자
초록
In this paper, A numerical analysis was performed to investigate effects of the Curved Vortex Generator(CVG) on heat transfer and flow characteristics of the finned-tube heat exchanger. The Delta Winglet Downstream(DWD) CVGs and Delta Winglet Upstream(DWU) CVGs were applied which placed on upstream and downstream of the tube, respectively. The DWD CVGs were fixed at 30, upstream of the tube, while only the position of the DWU CVGs were adjusted to figure out the effects. As the result, the closer DWU CVGs are to the tube, the smaller flow separation region of the tube. In addition, the DWU CVGs occur heat transfer enhancement on overall channel. This trend is commonly appeared at both 105 and 120. DWU CVGs at 105 and 120 with DWD CVGs, the lower results in the higher thermal performance factor. A nd t he f actors a re i ncreased b y 39 % a nd 3 6 % compared t o the plain finned- tube, respectively. A lso, T his increasement is higher than when applying a single pair of DWD CVGs or DWU CVGs. This results come from heat transfer enhancement by the mixed vortices of the DWD CVGs and the longitudinal vortices of the DWU CVGs, and reduction of separation region of tube by DWU CVGs.
키워드
Finned-tube Heat Exchanger(휜-튜브 열교환기)Vortex Generator(와류 발생기)Numerical Analysis(전산 해석)Longitudinal Vortices(종방향 와류)Flow Separation(유동 박리)Heat Transfer(열전달)Pressure Loss(압력 손실)Thermal Performance Factor(열 성능 팩터)
식별자
- KCI
- ART003106071



로그인
연구물 목록으로