본문 바로가기

Delta check limits for thyroid function tests adjusted for clinical settings

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q2Scopus Q1
저널
CLINICA CHIMICA ACTA561 · 2024
피인용
Web of Science 2Scopus 2
FWCI (Scopus)
0.28
JCR IF
JCR 2023 3.2
ISSN
0009-8981

저자

  1. Shin, Sunghwan제1저자Inje Univ, Coll Med, Ilsan Paik Hosp, Dept Lab Med, Goyang, South Korea
  2. Yu, ShinaeInje Univ, Coll Med, Haeundae Paik Hosp, Dept Lab Med, Pusan, South Korea
  3. Cho, Eun-jungHallym Univ, Coll Med, Dept Lab Med, Dongtan Sacred Heart Hosp, Hwaseong, South Korea
  4. 신경화Pusan Natl Univ, Pusan Natl Univ Hosp, Biomed Res Inst, Dept Lab Med,Sch Med, Busan 49241, South Korea
  5. Chung, Jae-WooDongguk Univ, Ilsan Hosp, Dept Lab Med, Goyang, South Korea
  6. Kim, Sollip교신저자Univ Ulsan, Asan Med Ctr, Dept Lab Med, Coll Med, 88,Olymp Ro 43 Gil, Seoul 05505, South Korea
  7. Yoo, Soo Jin교신저자Inje Univ, Sanggye Paik Hosp, Dept Lab Med, Coll Med, 1342 Dongil Ro, Seoul 01757, South Korea

초록

Background: This study aimed to determine practical delta check limits (DCLs) for thyroid function tests (TFTs) to detect sample misidentifications across various clinical settings. Methods: Between 2020 and 2022, 610,437 paired TFT results were collected from six university hospitals. The absolute DCL (absDCL) was determined using the 95th percentile for each clinical setting from a random 60 % of the total data. These absDCLs were then tested within and across different settings using the remaining 40 % of the data, alongside mix-up datasets for result and sample comparisons. The sensitivities of absDCL were calculated within and across groups in the mix-up datasets. Results: Health screening absDCLs were notably lower than in other settings (2.58 vs. 5.93–7.08 for thyroid-stimulating hormone; 4.12 vs. 8.24–10.04 for free thyroxine; 0.49 vs. 0.82–0.91 for total triiodothyronine). The proportion of results exceeding absDCL of health screening differed from those of other clinical settings. Furthermore, sensitivity between health screening and other clinical settings was significantly different in both the result mix-up and sample mix-up datasets. Conclusions: This study determined practical DCLs for TFTs and highlighted differences in absDCLs between health screening and other settings. These findings emphasize the importance of tailored DCLs in improving the accurate reporting of TFTs.

키워드

Delta checkFree T4Thyroid hormonesThyroid-stimulating hormoneTotal T3Q-PROBESBLOODLABORATORIESCRITERIARULES

식별자

Scopus EID
2-s2.0-85197506300
WoS UID
001269345000001