본문 바로가기

Construction of a sensitive SWCNTs integrated SPR biosensor for detecting PD-L1+exosomes based on Fe 3 O 4 @TiO 2 specific enrichment and signal amplification

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q1Scopus Q1
피인용
Web of Science 29Scopus 29
FWCI (Scopus)
2.95
JCR IF
JCR 2023 10.7
ISSN
0956-5663

저자

  1. Liu, Hezhen제1저자Shanghai Univ, Sch Life Sci, Shanghai 200444, Peoples R China
  2. Zhou, YangyangShanghai Univ, Sch Life Sci, Shanghai 200444, Peoples R China
  3. Chang, WeiweiShanghai Univ, Dept Phys, Shanghai 200444, Peoples R China
  4. Zhao, XinluoShanghai Univ, Dept Phys, Shanghai 200444, Peoples R China
  5. Hu, Xiaojun교신저자Shanghai Univ, Sch Life Sci, Shanghai 200444, Peoples R China
  6. 고광락교신저자Pusan Natl Univ, Inst Gen Educ, Busan 609735, South Korea
  7. Chen, Hongxia교신저자Shanghai Univ, Sch Life Sci, Shanghai 200444, Peoples R China

초록

Programmed cell death-ligand 1 positive (PD-L1+) exosomes play a crucial role in the realm of cancer diagnosis and treatment. Nevertheless, due to the intricate nature of biological specimens, coupled with the heterogeneity, low refractive index (RI), and scant surface coverage density of exosomes, traditional surface plasmon resonance (SPR) sensors still do not meet clinical detection requirements. This study utilizes the exceptional electrical and optical attributes of single-walled carbon nanotubes (SWCNTs) as the substrate for SPR sensing, thereby markedly enhancing sensitivity. Furthermore, sp2 hybridized SWCNTs have the ability to load specific recognition elements. Additionally, through the coordination interaction of Ti with phosphate groups and the ferromagnetism of Fe3O4, efficient exosomes isolation and enrichment in complex samples are achievable with the aid of an external magnetic field. Owing to the high-quality and high-RI of Fe3O4@TiO2, the response signal experiences amplification, thus further improving the performance of the SPR biosensor. The linear range of the SPR biosensor constructed by this method is 1.0 × 103 to 1.0 × 107 particles/mL, with a limit of detection (LOD) of 31.9 particles/mL. In the analysis of clinical serum samples, cancer patients can be differentiated from healthy individuals with an Area Under Curve (AUC) of 0.9835. This study not only establishes a novel platform for exosomes direct detection but also offers new perspectives for the sensitive detection of other biomarkers.

키워드

ExosomesFe3O4@TiO2PD-L1Signal amplificationSingle-walled carbon nanotubesSPRSURFACE-PLASMON RESONANCECARBON NANOTUBESNANOPARTICLESBIOMARKERSCOMPOSITEEFFICIENTEXOSOMESSENSORS

식별자

Scopus EID
2-s2.0-85196797790
WoS UID
001261938700001