Accuracy of generative deep learning model for macular anatomy prediction from optical coherence tomography images in macular hole surgery
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q1Scopus Q1
- 저널
- SCIENTIFIC REPORTS14(1) · 2024
- 피인용
- Web of Science 16Scopus 15
- FWCI (Scopus)
- 1.19
- JCR IF
- JCR 2023 3.8
- ISSN
- 2045-2322
저자
- 권한조제1저자Pusan Natl Univ, Sch Med, Biomed Res Inst, Pusan Natl Univ Hosp,Dept Ophthalmol, Gudeok Ro 179, Busan 49241, South Korea
- 허준Pusan Natl Univ, Sch Med, Biomed Res Inst, Pusan Natl Univ Hosp,Dept Ophthalmol, Gudeok Ro 179, Busan 49241, South Korea
- 박수환Pusan Natl Univ, Yangsan Hosp, Res Inst Convergence Biomed Sci & Technol, Dept Ophthalmol, Geumo Ro 20, Yangsan Si 50612, Gyeongsangnam D, South Korea
- 박성후Pusan Natl Univ, Sch Med, Biomed Res Inst, Pusan Natl Univ Hosp,Dept Ophthalmol, Gudeok Ro 179, Busan 49241, South Korea
- 변익수교신저자Pusan Natl Univ, Sch Med, Biomed Res Inst, Pusan Natl Univ Hosp,Dept Ophthalmol, Gudeok Ro 179, Busan 49241, South Korea
초록
This study aims to propose a generative deep learning model (GDLM) based on a variational autoencoder that predicts macular optical coherence tomography (OCT) images following full-thickness macular hole (FTMH) surgery and evaluate its clinical accuracy. Preoperative and 6-month postoperative swept-source OCT data were collected from 150 patients with successfully closed FTMH using 6 × 6 mm2 macular volume scan datasets. Randomly selected and augmented 120,000 training and 5000 validation pairs of OCT images were used to train the GDLM. We assessed the accuracy and F1 score of concordance for neurosensory retinal areas, performed Bland–Altman analysis of foveolar height (FH) and mean foveal thickness (MFT), and predicted postoperative external limiting membrane (ELM) and ellipsoid zone (EZ) restoration accuracy between artificial intelligence (AI)-OCT and ground truth (GT)-OCT images. Accuracy and F1 scores were 94.7% and 0.891, respectively. Average FH (228.2 vs. 233.4 μm, P = 0.587) and MFT (271.4 vs. 273.3 μm, P = 0.819) were similar between AI- and GT-OCT images, within 30.0% differences of 95% limits of agreement. ELM and EZ recovery prediction accuracy was 88.0% and 92.0%, respectively. The proposed GDLM accurately predicted macular OCT images following FTMH surgery, aiding patient and surgeon understanding of postoperative macular features.
키워드
Deep learningGenerative deep learning modelMacular holeOptical coherence tomographyVariational autoencoderINTERNAL LIMITING MEMBRANEVISUAL-ACUITYOUTCOMESVITRECTOMY
식별자
- Scopus EID
- 2-s2.0-85188470784
- WoS UID
- 001189439400005



로그인
연구물 목록으로